CVE-2026-3437 is a memory-bounds flaw in the driver shipped with Portwell Engineering Toolkits 4.8.2 and earlier, a Windows toolkit from Taiwan-based Portwell. A local user with an account on the machine can read and write arbitrary memory through the driver and escalate privileges or crash the system. NVD scores it 7.8. Portwell fixed it in version 5.0.0.
Vulnerability summary
CVSS base score
7.8
High severity
EPSS score (FIRST)
0.2%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2026-3437 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| Portwell Engineering Toolkits | cpe:2.3:a:portwell:engineering_toolkits:4.8.2:*:*:*:*:*:*:* | 4.8.2 and earlier (Portwell PWS-2026-3437, CVE record); NVD CPE lists 4.8.2. Fixed in 5.0.0 and later |
What does this mean for affected devices?
What is CVE-2026-3437?
NVD describes it as follows: "An improper restriction of operations within the bounds of a memory buffer vulnerability in Portwell Engineering Toolkits version 4.8.2 could allow a local authenticated attacker to read and write to arbitrary memory via the Portwell Engineering Toolkits driver. Successful exploitation of this vulnerability could result in escalation of privileges or cause a denial-of-service condition." The weakness is CWE-119. NVD's Primary CVSS v3.1 score is 7.8, vector CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. CISA, the CNA, scores it with a changed scope: 8.8 on CVSS v3.1 and 9.3 on CVSS v4.0 (NVD, CVE record).
What did CISA and Portwell publish?
CISA's ICS advisory ICSA-26-062-04 of 2026-03-03 credits Jason Huang of TXOne Networks' Cyber Threat & Product Defense Center and lists the Critical Manufacturing and Energy sectors, deployed worldwide, with company headquarters in Taiwan. At publication CISA wrote that Portwell had not responded to its coordination requests (CSAF record).
Portwell later published its own security advisory PWS-2026-3437: version 1.0 on 2026-06-18 and version 1.1 on 2026-07-03. It confirms that Engineering Toolkits 4.8.2 and earlier are affected on Windows systems and that version 5.0.0 and later fix the issue "by hardening the affected driver and restricting unsafe low-level hardware access paths". The CVE record was updated in June 2026 to list 5.0.0 as unaffected.
How do I fix it?
Upgrade Portwell Engineering Toolkits to 5.0.0 or the latest release, and remove the toolkit from machines that do not need it, since the risk sits in the installed driver. Portwell asks users to prioritize systems where local authenticated users may have access to the affected driver path. Driver bugs of this kind are memory-safety flaws; how to fix memory corruption in embedded firmware covers the class. KEV and EPSS vulnerability prioritization explains how to rank a local flaw like this one against remote ones.
Is CVE-2026-3437 exploited?
CISA reported no known public exploitation. The CVE is not in the CISA KEV catalog as of 2026-11-26 (catalog version 2026.11.25). FIRST EPSS gives 0.00203, the 5.85th percentile, in the 2026-11-25 dataset (FIRST EPSS).
Evidence
- NVD: Modified; memory buffer flaw in Portwell Engineering Toolkits 4.8.2 driver allows local authenticated arbitrary memory read/write; NVD Primary CVSS v3.1 7.8 AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H; CNA CVSS v3.1 8.8, v4.0 9.3; CNA CWE-119; CPE portwell:engineering_toolkits:4.8.2; published 2026-03-03; read 2026-11-26. — NVD
- CVE record (updated 2026-06-25): affected <= 4.8.2, unaffected v5.0.0; credit Jason Huang of TXOne Networks. — CVE.org
- ICSA-26-062-04 (2026-03-03): Critical Manufacturing and Energy, worldwide, HQ Taiwan; Portwell had not responded to CISA at publication. — CISA ICS Advisory ICSA-26-062-04
- CSAF icsa-26-062-04: product status Engineering Toolkits 4.8.2; CVSS v3.1 8.8; SSVC exploitation none. — CISA CSAF
- Portwell PWS-2026-3437 V1.0 2026-06-18, V1.1 2026-07-03: 4.8.2 and earlier affected on Windows systems; remediated in 5.0.0 and later by hardening the driver; prioritize systems where local users can access the driver path. — Portwell
- Not in the KEV catalog version 2026.11.25, checked 2026-11-26. — CISA KEV
- EPSS 0.00203, percentile 0.05853, dataset 2026-11-25. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which versions are affected by CVE-2026-3437?
Portwell Engineering Toolkits 4.8.2 and earlier, per Portwell advisory PWS-2026-3437 and the CVE record. NVD's CPE match names version 4.8.2.
Which version fixes CVE-2026-3437?
Version 5.0.0 and later. Portwell says the release hardens the affected driver and restricts unsafe low-level hardware access paths (per Portwell PWS-2026-3437).
Can CVE-2026-3437 be exploited remotely?
No. The attacker needs a local, authenticated account on the Windows system with the toolkit's driver installed; NVD's vector is AV:L/PR:L. The impact is privilege escalation or denial of service (per NVD).
Is CVE-2026-3437 in CISA KEV and what is its EPSS score?
It is not in the KEV catalog as of 2026-11-26 (catalog 2026.11.25). EPSS is 0.00203, the 5.85th percentile, in the 2026-11-25 dataset (per CISA KEV and FIRST EPSS).
Questions about this page?