Security Advisory

CVE-2026-33560: Daktronics DMP-5000 Arbitrary File Upload

Last updated:
  • CVE-2026-33560

CVE-2026-33560 is an unrestricted file upload (CWE-434) in the file service of Daktronics DMP-5000, DMP-8000 and VFC-DMP-5000 controllers: logged-in users can write executables and scripts to the device with no type or content check. NVD scores it 8.8 high. Daktronics fixes it in firmware 8.117.0.x, 9.43.0.x and 10.34.0.x.

Vulnerability summary

CVSS base score

8.8

High severity

EPSS score (FIRST)

0.4%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2026-33560 · Source: NVD (Primary CVSS v3.1)

Affected components

ComponentCPEVersion range
Daktronics DMP-5000 controllercpe:2.3:h:daktronics:dmp-5000:-:*:*:*:*:*:*:*Firmware before 8.117.0.0, 9.0.0.0 to before 9.43.0.0, 10.0.0.0 to before 10.34.0.0 (NVD); fixed in 8.117.0.x, 9.43.0.x or 10.34.0.x (Daktronics via CISA)
Daktronics DMP-8000 controllercpe:2.3:h:daktronics:dmp-8000:-:*:*:*:*:*:*:*Same three firmware branches and fixed versions as the DMP-5000
Daktronics VFC-DMP-5000 controllercpe:2.3:h:daktronics:vfc-dmp-5000:-:*:*:*:*:*:*:*Same three firmware branches and fixed versions as the DMP-5000

What does this mean for affected devices?

NVD analyzed CVE-2026-33560 and gives it a Primary CVSS v3.1 score of 8.8 (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). CISA, the CNA, scores it CVSS v3.1 7.1 (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N) and CVSS v4 8.4, and assigns CWE-434 (Unrestricted Upload of File with Dangerous Type). Both vectors require a login; NVD rates confidentiality and availability impact higher. The CVE record, published 2026-06-26, says exposed endpoints let authenticated users "upload files of any type without validation" and that "no file extension filtering or content inspection is enforced", so "executable binaries and scripts" are "written directly to the server" (NVD, CVE record).

Which Daktronics controllers are affected?

CISA advisory ICSA-26-176-04, published 2026-06-25, lists the DMP-5000, DMP-8000 and VFC-DMP-5000 with firmware below 8.117, 9.43 or 10.34 on its branch (CISA lists <v8.117.x.x, <v9.43.x.x and <v10.34.x.x for each model), in the Commercial Facilities, Information Technology, Emergency Services and Healthcare and Public Health sectors. The same advisory covers CVE-2026-31928, a default administrative web account, CVE-2026-33560, an authenticated arbitrary file upload, and CVE-2026-28701, a path traversal. The login this flaw needs is the weak point: the default account in CVE-2026-31928 gives exactly that access on a unit where it was never changed.

How do I fix CVE-2026-33560?

Daktronics recommends updating the device software to 8.117.0.x, 9.43.0.x or 10.34.0.x, whichever matches the product configuration in use, and replacing default passwords with strong, unique credentials per device. NVD encodes the same boundaries in its CPE ranges: firmware before 8.117.0.0, 9.0.0.0 up to 9.43.0.0, and 10.0.0.0 up to 10.34.0.0 for each of the three models. Daktronics publishes a security disclosure page for reporting product vulnerabilities; it carries no advisory for these CVEs as of 2026-11-26, so the CISA advisory is the reference. On units that were reachable with default passwords before the update, check the file store for files nobody on your team placed there.

Until every unit is updated, keep controllers off the internet, behind a firewall and isolated from business networks, as CISA recommends. Unrestricted upload is not in one of our CWE fix-guide classes; the closest developer guidance is how to fix input-handling weaknesses in embedded firmware, and the patch rollout itself follows NIST SP 800-40 patch management.

Is CVE-2026-33560 exploited?

CISA reported no known public exploitation when it published the advisory. CVE-2026-33560 is not in the CISA KEV catalog as of 2026-11-26 (catalog version 2026.11.25) (CISA KEV). FIRST EPSS gives 0.00444, the 30.51st percentile, in the 2026-11-25 dataset (FIRST EPSS).

How to fix this class of issueNo dedicated SoftWSP guide covers this weakness class; the fix is usually the vendor patch or firmware update referenced above. Our related guide explains how to plan and verify it: NIST SP 800-40 Rev. 4: enterprise patch management planning, explained.

Evidence

  • NVD: status Analyzed; Primary CVSS v3.1 8.8 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H ([email protected]); CISA Secondary CVSS v3.1 7.1 and v4 8.4; CWE-434 (CISA); CPE ranges as CVE-2026-31928; published 2026-06-26; read 2026-11-26. — NVD
  • CVE record: CNA CISA ICS (icscert), published 2026-06-26; same three products and branches; CVSS v3.1 7.1, v4 8.4; CWE-434. — CVE.org
  • ICSA-26-176-04 (2026-06-25) "Daktronics Controller Firmware": VFC-DMP-5000, DMP-5000, DMP-8000 <v8.117.x.x, <v9.43.x.x, <v10.34.x.x; CVE-2026-28701, CVE-2026-33560, CVE-2026-31928; sectors Commercial Facilities, Information Technology, Emergency Services, Healthcare and Public Health; HQ United States; mitigation update to 8.117.0.x, 9.43.0.x or 10.34.0.x and change default passwords; no known public exploitation; reported by Thomas Jou, Princeton University. — CISA ICS advisory
  • CSAF ICSA-26-176-04: CVE-2026-33560 CVSS v3.1 7.1; mitigation text. — CISA CSAF
  • Daktronics security disclosure page: reporting form and SSIRT contact; no advisory for these CVEs; read 2026-11-26. — Daktronics
  • KEV catalog 2026.11.25: CVE-2026-33560 not listed; checked 2026-11-26. — CISA KEV
  • EPSS 0.00444, percentile 0.30513, dataset 2026-11-25, read 2026-11-26. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CVE.org record CVE-2026-33560 (CNA: CISA ICS)
  3. CISA ICS advisory ICSA-26-176-04
  4. CISA CSAF ICSA-26-176-04
  5. Daktronics security disclosure
  6. CISA KEV
  7. FIRST EPSS

Frequently asked questions

What is CVE-2026-33560?

An unrestricted file upload in the file service of Daktronics DMP-5000, DMP-8000 and VFC-DMP-5000 controllers: authenticated users can upload any file type, including executables and scripts, with no extension filtering or content inspection (per the CVE record and CISA ICSA-26-176-04).

Does an attacker need to log in for CVE-2026-33560?

Yes. Both the NVD and CISA vectors require low privileges. The same advisory lists a default administrative web account, CVE-2026-31928, which supplies such a login on units where it was never changed (per NVD and CISA).

Which firmware fixes CVE-2026-33560?

Daktronics recommends 8.117.0.x, 9.43.0.x or 10.34.0.x, depending on the product configuration, and strong, unique passwords per device (per CISA ICSA-26-176-04).

What are the KEV and EPSS values for CVE-2026-33560?

It is not in the CISA KEV catalog as of 2026-11-26. FIRST EPSS gives 0.00444, the 30.51st percentile, in the 2026-11-25 dataset (per CISA KEV and FIRST EPSS).