CVE-2025-40602 is a privilege escalation caused by insufficient authorization in the Appliance Management Console of SonicWall SMA1000 remote access appliances. On its own it is rated 6.6, but attackers chained it with CVE-2025-23006 to get unauthenticated root-level code execution, and CISA KEV lists it. Install hotfix 12.4.3-03245 or 12.5.0-02283 or later and keep the console off the internet.
Vulnerability summary
CVSS base score
6.6
Medium severity
EPSS score (FIRST)
2.8%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
Yes
Listed as known exploited
Published
Vulnerability ID: CVE-2025-40602 · Source: NVD (CISA-ADP Secondary score only, not NVD Primary)
Affected components
| Component | CPE | Version range |
|---|---|---|
| SonicWall SMA1000 series (SMA 6200, 6210, 7200, 7210, 8200v) | cpe:2.3:o:sonicwall:sma6200_firmware:*:*:*:*:*:*:*:* | 12.4.3-03093 and earlier, 12.5.0-02002 and earlier (platform-hotfix, SNWLID-2025-0019); fixed in 12.4.3-03245 and 12.5.0-02283 (platform-hotfix) and higher |
What does this mean for affected devices?
SonicWall, the CNA, published the CVE record on 2025-12-18: "A local privilege escalation vulnerability due to insufficient authorization in the SonicWall SMA1000 appliance management console (AMC)." NVD has no Primary score of its own: the only CVSS on the NVD page is CISA-ADP's CVSS v3.1 6.6 (CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H), labelled Secondary. SonicWall's advisory gives 6.6 as a CVSS v3.0 score and names CWE-862 (missing authorization) and CWE-250 (execution with unnecessary privileges). NVD does list CPEs: SMA 6200, 6210, 7200 and 7210 firmware and the SMA 8200v before 12.4.3-03245, and 12.5.0 before 12.5.0-02283. The CISA KEV listing is what qualifies this page (NVD, CVE record).
Which SMA1000 builds fix CVE-2025-40602?
SonicWall's advisory SNWLID-2025-0019 of 2025-12-17 lists SMA1000 12.4.3-03093 (platform-hotfix) and earlier and 12.5.0-02002 (platform-hotfix) and earlier as affected, and 12.4.3-03245 and 12.5.0-02283 (platform-hotfix) and higher as fixed; the hotfixes are on mysonicwall.com. SSL-VPN on SonicWall firewalls is not affected. As a workaround SonicWall says to restrict the AMC, allowing SSH only via VPN or from specific admin IPs, and to disable AMC and SSH access from the public internet. Credit goes to Clément Lecigne and Zander Work of Google Threat Intelligence Group.
Why is a 6.6 flaw on the KEV list?
Because of the chain. SonicWall's advisory says CVE-2025-40602 was reported used together with the pre-authentication deserialization CVE-2025-23006 (CVSS 9.8, fixed in 12.4.3-02854 in January 2025) to gain unauthenticated remote code execution with root privileges. SonicWall adds that the only known exploitation paths need either an unpatched CVE-2025-23006 or an attacker who already has a local system account. Both flaws are in the management console, which CISA BOD 23-02 on internet-exposed management interfaces says to keep off the internet.
What does CISA require?
CISA added it to the KEV catalog on 2025-12-17 with the required action "Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable" (due date 2025-12-24; known ransomware campaign use: Unknown) and a note to check all internet-accessible SMA1000 instances for signs of compromise after applying mitigations. It is still listed as of 2026-11-25 in catalog version 2026.11.24 (CISA KEV). FIRST EPSS gives 0.02766, the 86.561st percentile, in the 2026-11-24 dataset (FIRST EPSS). A low EPSS does not outrank a KEV listing; see KEV and EPSS vulnerability prioritization.
Evidence
- NVD: status Analyzed; local privilege escalation due to insufficient authorization in SMA1000 AMC; only metric CISA-ADP (134c704f) Secondary CVSS v3.1 6.6 AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H; no NVD Primary score; CWE-250 and CWE-862 from SonicWall (Secondary); CPEs sma6200/6210/7200/7210 firmware and sma8200v < 12.4.3-03245 and 12.5.0 to < 12.5.0-02283; published 2025-12-18; read 2026-11-25. — NVD
- CVE record: PUBLISHED, CNA SonicWall, 2025-12-18; SMA1000 12.4.3-03093 (platform-hotfix) and earlier, 12.5.0-02002 (platform-hotfix) and earlier affected; CISA-ADP CVSS 3.1 6.6. — CVE.org
- SonicWall SNWLID-2025-0019 (read via psirtapi JSON): published 2025-12-17, rev 1.1 2025-12-18; CVSS v3.0 6.6; CWE-862, CWE-250; affected 12.4.3-03093 and 12.5.0-02002 (platform-hotfix) and earlier; fixed 12.4.3-03245 and 12.5.0-02283 and higher; firewall SSL-VPN not affected; workaround restrict AMC, SSH via VPN or admin IPs only, disable AMC and SSH from the public internet; leveraged in combination with CVE-2025-23006 for unauthenticated RCE with root; known exploitation needs unpatched CVE-2025-23006 or local system account; credit Clément Lecigne and Zander Work (GTIG). — SonicWall PSIRT
- SonicWall SNWLID-2025-0002: CVE-2025-23006 fixed in 12.4.3-02854 (platform-hotfix). — SonicWall PSIRT
- KEV catalog 2026.11.24: dateAdded 2025-12-17, due 2025-12-24, required action 'Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable'; ransomware Unknown; notes: check internet-accessible SMA1000 instances for compromise after mitigations; CWE-862, CWE-250; checked 2026-11-25. — CISA KEV
- EPSS 0.02766, percentile 0.86561, dataset 2026-11-24, read 2026-11-25. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which SMA1000 versions are affected by CVE-2025-40602?
SMA1000 12.4.3-03093 (platform-hotfix) and earlier and 12.5.0-02002 (platform-hotfix) and earlier. NVD's CPEs name the SMA 6200, 6210, 7200, 7210 and 8200v. SSL-VPN on SonicWall firewalls is not affected (per SNWLID-2025-0019 and NVD).
Which hotfix fixes CVE-2025-40602?
12.4.3-03245 (platform-hotfix) and higher on the 12.4.3 line, and 12.5.0-02283 (platform-hotfix) and higher on the 12.5.0 line, available on mysonicwall.com (per SNWLID-2025-0019).
Why does NVD show only a 6.6 score from CISA for CVE-2025-40602?
As of 2026-11-25 NVD has no Primary score for this CVE; the 6.6 on its page is CISA-ADP's Secondary score, which matches SonicWall's 6.6. The page qualifies through its CISA KEV listing of 2025-12-17 (per NVD and CISA KEV).
Is my appliance at risk if CVE-2025-23006 is already patched?
Less so. SonicWall says the only known exploitation paths need an unpatched CVE-2025-23006 or an attacker who already holds a local system account. Still install the fixed hotfix and check internet-facing SMA1000 appliances for signs of compromise, as CISA's KEV note asks (per SNWLID-2025-0019 and CISA KEV).
Questions about this page?