Security Advisory

CVE-2025-27939: Growatt Cloud Portal Account Takeover

Last updated:
  • CVE-2025-27939

CVE-2025-27939 is an authorization bypass (CWE-639) in the Growatt cloud portal, the vendor cloud that Growatt solar inverters connect to. An attacker could change another user's registered email address and take over the account. NVD scores it 7.5 high. Growatt reports that the cloud flaw is patched and that users need to take no action.

Vulnerability summary

CVSS base score

7.5

High severity

EPSS score (FIRST)

0.6%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2025-27939 · Source: NVD

Affected components

ComponentCPEVersion range
Growatt cloud portalcpe:2.3:a:growatt:cloud_portal:*:*:*:*:*:*:*:*3.6.0 and prior (CISA ICSA-25-105-04, NVD CPE up to and including 3.6.0); patched server-side by Growatt

What does this mean for affected devices?

NVD describes CVE-2025-27939 as follows: "An attacker can change registered email addresses of other users and take over arbitrary accounts." NVD's own Primary CVSS v3.1 score is 7.5 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N), the same as the CNA score from CISA ICS; CISA also gives CVSS v4 6.9. NVD's CPE configuration covers the Growatt cloud portal up to and including 3.6.0, and the weakness is CWE-639, authorization bypass through a user-controlled key (NVD, CVE record).

Why does a cloud account flaw matter for solar devices?

CISA advisory ICSA-25-105-04 of 2025-04-15 covers Growatt cloud applications, the Energy sector, worldwide deployment and a vendor based in China. It lists 30 CVEs, most of them CWE-639 flaws that let an attacker act on other users' accounts, plants and devices; CISA states that exploitation could compromise confidentiality, enable cross-site scripting or achieve code execution on affected devices. The research came from Forescout Vedere Labs, whose SUN:DOWN report found 46 new vulnerabilities in solar power products from Sungrow, SMA and Growatt. Forescout notes that inverters are connected to the grid and to the vendor's cloud, and that the flaws could let attackers gain access to vulnerable inverters and tamper with their configurations, which could cause power grid instability. A separate Growatt device flaw on this site is CVE-2025-36752 for the ShineLan-X communication dongle.

Do I need to do anything about CVE-2025-27939?

According to CISA, Growatt reports that the cloud-based vulnerabilities were patched and that no user action is needed. Growatt also recommends updating devices to the latest firmware (updates are automatic), using strong passwords with multi-factor authentication where available, reviewing security settings regularly and reporting concerns to the vendor (CSAF file). For operators of distributed solar sites, NIST SP 1800-32 on securing distributed energy resources covers security for distributed energy resources such as solar inverters, and KEV and EPSS vulnerability prioritization explains how to rank a flaw like this against device firmware CVEs.

Is CVE-2025-27939 exploited?

It is absent from the CISA KEV catalog as of 2026-11-26 (catalog version 2026.11.25), and the CISA advisory reported no known public exploitation at publication. FIRST EPSS gives 0.00599, the 42.72nd percentile, in the 2026-11-25 dataset (FIRST EPSS).

How to fix this class of issueNo dedicated SoftWSP guide covers this weakness class; the fix is usually the vendor patch or firmware update referenced above. Our related guide explains how to plan and verify it: NIST SP 800-40 Rev. 4: enterprise patch management planning, explained.

Evidence

  • NVD: Analyzed; Primary CVSS v3.1 7.5 AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N; CISA ICS v3.1 7.5 and v4 6.9; CWE-639; CPE growatt cloud_portal up to and including 3.6.0; published 2025-04-15; read 2026-11-26. — NVD
  • CVE record: PUBLISHED by CISA ICS 2025-04-15; Cloud portal less than 3.6.0; credit Forescout Technologies. — CVE.org
  • ICSA-25-105-04 (2025-04-15, revised 2025-05-06 for typos): Growatt cloud portal <= 3.6.0; 30 CVEs, mostly CWE-639; Energy sector; HQ China; Growatt reports cloud vulnerabilities patched, no user action needed; firmware updates automatic; strong passwords and MFA; no known public exploitation reported. — CISA ICS advisory
  • Forescout SUN:DOWN: 46 new vulnerabilities in Sungrow, SMA and Growatt solar products ; inverters connect to the grid and the vendor cloud; attackers could gain access to vulnerable inverters and tamper with configurations, causing grid instability; read 2026-11-26. — Forescout
  • Not in the KEV catalog, version 2026.11.25, checked 2026-11-26. — CISA KEV
  • EPSS 0.00599, percentile 0.42721, dataset 2026-11-25. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CVE.org record CVE-2025-27939 (CNA: CISA ICS)
  3. CISA ICS advisory ICSA-25-105-04
  4. CISA CSAF file ICSA-25-105-04
  5. Forescout Vedere Labs: SUN:DOWN
  6. CISA KEV
  7. FIRST EPSS

Frequently asked questions

Which Growatt cloud portal versions are affected by CVE-2025-27939?

CISA lists the Growatt cloud portal 3.6.0 and prior, and NVD's CPE covers versions up to and including 3.6.0. Growatt reports the flaw is patched on the server side (per CISA ICSA-25-105-04 and NVD).

Do Growatt users need to install anything to fix CVE-2025-27939?

No. Growatt reports that the cloud-based vulnerabilities were patched and that no user action is needed. It still recommends strong passwords, multi-factor authentication and the latest device firmware, which updates automatically (per CISA).

Who found CVE-2025-27939?

Forescout Technologies reported it to CISA. Forescout Vedere Labs published the findings as SUN:DOWN, covering 46 new vulnerabilities in Sungrow, SMA and Growatt solar products (per the CVE record and Forescout).

Is CVE-2025-27939 in the CISA KEV catalog?

No. It is absent from KEV catalog version 2026.11.25 as of 2026-11-26, and FIRST EPSS gives 0.00599 (42.72nd percentile) in the 2026-11-25 dataset (per CISA KEV and FIRST EPSS).