Security Advisory

CVE-2024-1212: Kemp LoadMaster Unauth Command Injection

Last updated:
  • CVE-2024-1212

CVE-2024-1212 is an unauthenticated OS command injection in the management interface of Progress Kemp LoadMaster: a remote attacker with no login can run system commands on the load balancer. NVD scores it 9.8 (Progress 10.0) and CISA KEV lists it. Update LoadMaster to 7.2.59.2, 7.2.54.8 or 7.2.48.10 or later.

Vulnerability summary

CVSS base score

9.8

Critical severity

EPSS score (FIRST)

77.4%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

Yes

Listed as known exploited

Published

Vulnerability ID: CVE-2024-1212 · Source: NVD (Primary CVSS v3.1)

Affected components

ComponentCPEVersion range
Progress Kemp LoadMaster (LMOS)cpe:2.3:o:progress:loadmaster:*:*:*:*:*:*:*:*7.2.48.1 to before 7.2.48.10, 7.2.54.0 to before 7.2.54.8, 7.2.55.0 to before 7.2.59.2 (CVE record, NVD); fixed in 7.2.48.10, 7.2.54.8, 7.2.59.2 (Progress release notice 2024-02-07)

What does this mean for affected devices?

The CVE record, published on 2024-02-21 by Progress Software as CNA, says that "unauthenticated remote attackers can access the system through the LoadMaster management interface, enabling arbitrary system command execution". NVD's Primary CVSS v3.1 score is 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) with CWE-78; Progress scores it 10.0 with a changed scope (NVD, CVE record). Kemp LoadMaster is a load balancer and application delivery controller sold as hardware and virtual appliances, so its management interface sits in front of the applications it serves.

Which LoadMaster releases are affected?

The CVE record and NVD's CPE configuration list three LoadMaster OS (LMOS) trains: 7.2.48.1 up to but not including 7.2.48.10, 7.2.54.0 up to but not including 7.2.54.8, and 7.2.55.0 up to but not including 7.2.59.2. The affected module is the LoadMaster management interface.

How do you fix it?

Progress's release notice of 7 February 2024 names LMOS 7.2.59.2, 7.2.54.8 and 7.2.48.10 and says "it is vital to the security of your LoadMaster that you update your LoadMaster to one of these releases as soon as possible". Pick the fixed release on your train, or a later one. Since the attack needs no login, also keep the management interface off the internet and reachable only from an admin network; see the BOD 23-02 guide on internet-exposed management interfaces. A later exploited LoadMaster command injection, CVE-2026-8037, affects much newer releases, so upgrading only to the 2024 builds is not enough today. The class fix is in how to fix command injection in embedded firmware.

Is CVE-2024-1212 exploited?

Yes. CISA added it to the KEV catalog on 2024-11-18 with the required action "Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable." (due 2024-12-09); known ransomware campaign use is "Unknown". It is still listed in catalog version 2026.11.25 (as of 2026-11-26). FIRST EPSS gives 0.77387, the 99.69th percentile, in the 2026-11-25 dataset (FIRST EPSS), so both KEV and EPSS put it at the top of the queue (KEV and EPSS vulnerability prioritization).

How to fix this class of issueThis advisory's weakness class is Command injection. Our practical guide covers how to detect, fix, verify and disclose it: How to fix command injection in embedded firmware.

Evidence

  • NVD: status Analyzed, published 2024-02-21; unauthenticated remote attackers can access the system through the LoadMaster management interface, enabling arbitrary system command execution; NVD Primary CVSS v3.1 9.8, CWE-78; Progress Secondary 10.0; CPE loadmaster 7.2.48.1-<7.2.48.10, 7.2.54.0-<7.2.54.8, 7.2.55.0-<7.2.59.2; read 2026-11-26. — NVD
  • CVE record: PUBLISHED, CNA ProgressSoftware; module LoadMaster Management Interface; same three ranges; CVSS 3.1 10.0. — CVE.org
  • Progress release notice dated 07 February 2024: LMOS 7.2.59.2, 7.2.54.8 and 7.2.48.10 for CVE-2024-1212; 'It is vital to the security of your LoadMaster that you update your LoadMaster to one of these releases as soon as possible.' Read via fetch 2026-11-26. — Progress Kemp release notice
  • KEV catalog 2026.11.25: dateAdded 2024-11-18, dueDate 2024-12-09, required action 'Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.', knownRansomwareCampaignUse Unknown, CWE-78; read 2026-11-26. — CISA KEV
  • EPSS 0.77387, percentile 0.99691, dataset 2026-11-25, read 2026-11-26. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. Progress release notice: LMOS 7.2.59.2, 7.2.54.8, 7.2.48.10 (CVE-2024-1212)
  3. CVE.org record CVE-2024-1212 (CNA: Progress Software)
  4. CISA KEV
  5. FIRST EPSS

Frequently asked questions

Which LoadMaster versions are affected by CVE-2024-1212?

LMOS 7.2.48.1 up to 7.2.48.10, 7.2.54.0 up to 7.2.54.8 and 7.2.55.0 up to 7.2.59.2, each upper bound excluded (per the CVE record and NVD).

Which LoadMaster release fixes CVE-2024-1212?

Progress's release notice of 7 February 2024 names LMOS 7.2.59.2, 7.2.54.8 and 7.2.48.10 and asks customers to update to one of them as soon as possible. Later releases also fix later flaws such as CVE-2026-8037 (per Progress).

Does CVE-2024-1212 need credentials?

No. The CVE record says unauthenticated remote attackers can reach the system through the management interface, so an internet-exposed interface is directly at risk (per the CVE record and NVD).

Is CVE-2024-1212 exploited?

Yes. CISA added it to KEV on 2024-11-18; ransomware use is listed as Unknown. FIRST EPSS gives 0.77387 (99.69th percentile) in the 2026-11-25 dataset (as of 2026-11-26, per CISA KEV and FIRST EPSS).