Security Advisory

CVE-2024-1039: Gessler WEB-MASTER Hard-Coded Login

Last updated:
  • CVE-2024-1039

CVE-2024-1039 is a hard-coded credential (CWE-798) in Gessler GmbH WEB-MASTER 7.9: a restoration account with weak built-in credentials could give an attacker control over the device's web management. NVD scores it 9.8 critical. Gessler's fix is EZ2 3.2 or later and WebMaster 4.4 or later, installed by Gessler technicians.

Vulnerability summary

CVSS base score

9.8

Critical severity

EPSS score (FIRST)

1.0%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2024-1039 · Source: NVD

Affected components

ComponentCPEVersion range
Gessler GmbH WEB-MASTERcpe:2.3:o:gesslergmbh:web-master_firmware:7.9:*:*:*:*:*:*:*Version 7.9 (CISA ICSA-24-032-01, NVD CPE, CVE record); fix: EZ2 3.2 or greater and WebMaster 4.4 or greater, applied by Gessler technicians

What does this mean for affected devices?

NVD describes CVE-2024-1039 as follows: Gessler GmbH WEB-MASTER "has a restoration account that uses weak hard coded credentials and if exploited could allow an attacker control over the web management of the device." CISA ICS, the CNA, classifies it as CWE-798, use of hard-coded credentials; NVD's own weakness entry is CWE-287, improper authentication. NVD's Primary CVSS v3.1 score is 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H), the same as the CISA score, and its CPE names WEB-MASTER firmware 7.9 (NVD, CVE record).

What does CISA say about Gessler WEB-MASTER?

CISA advisory ICSA-24-032-01 of 2024-02-01 (revised 2025-08-07 to update the CWEs) covers WEB-MASTER version 7.9. Gessler GmbH is a German maker of safety lighting and emergency power systems (Gessler); CISA lists the Critical Manufacturing sector and worldwide deployment. The advisory has a second CVE, CVE-2024-1040 (CWE-327, NVD 4.4), because user passwords are stored with a weak hashing algorithm. CISA states that exploitation could let a user take control of the web management of the device, and that an attacker with access to the device could extract and break the password hashes of all users stored on it. Felix Eberstaller and Nino Fürthauer of Limes Security reported the issues.

How do you fix CVE-2024-1039?

Gessler recommends updating EZ2 to 3.2 or greater and WebMaster to 4.4 or greater. The update has to be applied by Gessler technicians; for more information, contact Gessler (CSAF file). Until then, CISA's general advice applies: keep the web interface off the internet, behind a firewall and separated from business networks. The hard-coded credentials fix guide covers how device makers find and remove service accounts like this one, and the weak cryptography fix guide covers the password hashing flaw. Another building safety device on this site is the Gira KNX IP router flaw CVE-2023-33277.

Is CVE-2024-1039 exploited?

It is absent from the CISA KEV catalog as of 2026-11-26 (catalog version 2026.11.25), and CISA reported no known public exploitation at publication. FIRST EPSS gives 0.00968, the 60.49th percentile, in the 2026-11-25 dataset (FIRST EPSS).

How to fix this class of issueThis advisory's weakness class is Hard-coded credentials. Our practical guide covers how to detect, fix, verify and disclose it: How to fix hard-coded credentials in embedded firmware.

Evidence

  • NVD: Modified; Primary CVSS v3.1 9.8 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H; CISA ICS 9.8 same vector; weaknesses CWE-798 (CISA) and CWE-287 (NVD); CPE gesslergmbh web-master_firmware 7.9; published 2024-02-01; read 2026-11-26. — NVD
  • CVE record: PUBLISHED by CISA ICS 2024-02-01, title Use of Hard-coded Credentials in Gessler GmbH WEB-MASTER; affected 7.9; CVSS v3.1 9.8; credit Felix Eberstaller and Nino Fürthauer of Limes Security. — CVE.org
  • ICSA-24-032-01 (2024-02-01, revised 2025-08-07 for CWEs): WEB-MASTER 7.9; CVE-2024-1039 CWE-798 and CVE-2024-1040 CWE-327; Critical Manufacturing; HQ Germany; Gessler recommends EZ2 3.2+ and WebMaster 4.4+, applied by Gessler technicians; no known public exploitation reported. — CISA ICS advisory
  • Gessler home page title: Sicherheitsbeleuchtung und Notstromsysteme (safety lighting and emergency power systems); read 2026-11-26. — Gessler
  • Not in the KEV catalog, version 2026.11.25, checked 2026-11-26. — CISA KEV
  • EPSS 0.00968, percentile 0.60493, dataset 2026-11-25. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CVE.org record CVE-2024-1039 (CNA: CISA ICS)
  3. CISA ICS advisory ICSA-24-032-01
  4. CISA CSAF file ICSA-24-032-01
  5. Gessler GmbH (vendor home page)
  6. CISA KEV
  7. FIRST EPSS

Frequently asked questions

Which Gessler WEB-MASTER version is affected by CVE-2024-1039?

CISA, NVD and the CVE record all name WEB-MASTER version 7.9 (per CISA ICSA-24-032-01 and NVD).

How is CVE-2024-1039 fixed?

Gessler recommends updating EZ2 to 3.2 or greater and WebMaster to 4.4 or greater. Gessler technicians have to apply the update, so contact Gessler (per CISA ICSA-24-032-01).

What is the other vulnerability in the same Gessler advisory?

CVE-2024-1040: WEB-MASTER stores user passwords with a weak hashing algorithm (CWE-327), so an attacker with access to the device could extract and break the hashes. NVD scores it 4.4 (per CISA ICSA-24-032-01 and NVD).

Is CVE-2024-1039 in the CISA KEV catalog?

No. It is absent from KEV catalog version 2026.11.25 as of 2026-11-26, and FIRST EPSS gives 0.00968 (60.49th percentile) in the 2026-11-25 dataset (per CISA KEV and FIRST EPSS).