Security Advisory

CVE-2023-4485: ARDEREG Sistemas SCADA Login SQL Injection

Last updated:
  • CVE-2023-4485

CVE-2023-4485 is an unauthenticated blind SQL injection in the login page of ARDEREG Sistemas SCADA, versions 2.203 and prior. An attacker who reaches the login form can run arbitrary SQL against the SCADA database without an account. NVD and CISA score it 9.8. ARDEREG lists only workarounds and no fixed version, so network isolation is the main defence.

Vulnerability summary

CVSS base score

9.8

Critical severity

EPSS score (FIRST)

0.9%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2023-4485 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
ARDEREG Sistemas SCADA (Sistema SCADA Central)cpe:2.3:a:ardereg:sistemas_scada:*:*:*:*:*:*:*:*2.203 and prior (CISA ICSA-23-243-01, CVE record; NVD up to and including 2.203); no fixed version listed as of 2026-11-27

What does this mean for affected devices?

The CVE record from CISA says that the login page of ARDEREG Sistema SCADA Central, versions 2.203 and prior, is "vulnerable to an unauthenticated blind SQL injection attack". An attacker "could manipulate the application's SQL query logic to extract sensitive information or perform unauthorized actions within the database", with possible results of "unauthorized access, data leakage, or even disruption of critical industrial processes." NVD's Primary score and CISA's score are both 9.8, CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, and both map it to CWE-89. NVD's configuration covers Sistemas SCADA up to and including 2.203 (NVD, CVE record).

Who uses ARDEREG Sistemas SCADA?

CISA's ICSA-23-243-01, released on 2023-08-31, lists Sistemas SCADA 2.203 and prior as the only affected product. CISA tags the sector as Healthcare and Public Health, with deployment in South America; ARDEREG is based in Argentina. Momen Eldawakhly of Samurai Digital Security reported the flaw to CISA. The SCADA server is the place where operators log in to supervise a process, so a flaw in the login page is reachable by anyone who can reach that server.

How do you mitigate CVE-2023-4485?

CISA records that ARDEREG "is aware of the issue but has not responded" to its requests, and refers users to ARDEREG by email. The vendor's listed workarounds are general practice: security training for developers and operators, regular security assessments with penetration tests and code reviews, an incident response plan for SQL injection, supply chain checks, and network segmentation that isolates the SCADA system from less critical and public-facing networks. Of these, segmentation is the one that lowers the risk today:

  • keep the SCADA login page off the internet and off general office networks;
  • allow access to the server only from operator workstations and a VPN for remote staff;
  • put a web application firewall or reverse proxy with SQL injection rules in front of the login page if it must be reachable more widely;
  • review database accounts so the SCADA application cannot read more than it needs.

Ask ARDEREG whether a release later than 2.203 changes the login query handling. SQL injection in OT web front ends also appears in CVE-2024-8630 (Alisonic Sibylla tank gauge) and CVE-2021-32983 (Delta DIAEnergie). The input handling fix guide covers parameterised queries, and the small manufacturers OT guide covers segmentation.

Is CVE-2023-4485 exploited?

CVE-2023-4485 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS gives it 0.00924, the 58.71st percentile, in the 2026-11-26 dataset (CISA KEV, FIRST EPSS). At release, CISA reported no known public exploitation specifically targeting this vulnerability.

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is SQL injection. Our practical guide covers how to detect, fix, verify and disclose it: How to fix SQL injection, XSS, resource exhaustion and deserialization flaws in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • NVD (read 2026-11-27): status Modified; published 2023-09-06; NVD Primary CVSS v3.1 9.8 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, ICS-CERT Secondary 9.8; CWE-89 (NVD and CISA); CPE ardereg sistemas_scada up to and including 2.203. — NVD
  • CISA ICSA-23-243-01 CSAF (released 2023-08-31, read 2026-11-27): Sistemas SCADA <= 2.203; CVE-2023-4485 CWE-89 9.8; ARDEREG aware but has not responded, contact [email protected]; vendor workarounds (training, assessments, incident response plan, supply chain security, system segmentation); Healthcare and Public Health, South America, HQ Argentina; credit Momen Eldawakhly (Samurai Digital Security); no known public exploitation reported. — CISA ICSA-23-243-01
  • CVE record (checked 2026-11-27): PUBLISHED, CNA ICS-CERT, published 2023-09-05; CNA CVSS v3.1 9.8, CWE-89; affected Sistemas SCADA 0 to 2.203. — CVE.org
  • Not in the CISA KEV catalog, catalog version 2026.11.25, 1,805 entries, checked 2026-11-27. — CISA KEV
  • EPSS 0.00924, percentile 0.58708, dataset 2026-11-26, read 2026-11-27. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICSA-23-243-01: ARDEREG Sistemas SCADA (CSAF)
  3. CISA ICSA-23-243-01 advisory page
  4. CVE.org record CVE-2023-4485
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Which ARDEREG versions are affected by CVE-2023-4485?

Sistemas SCADA (Sistema SCADA Central) 2.203 and prior, per CISA ICSA-23-243-01, the CVE record and NVD.

Is there a patch for CVE-2023-4485?

No fixed version is listed. CISA records that ARDEREG is aware of the issue but did not respond to CISA; the vendor's workarounds centre on segmentation, assessments and incident response. Ask ARDEREG directly whether a later release addresses it.

Does an attacker need an account?

No. The injection is in the login page and is unauthenticated, which is why NVD and CISA both score it 9.8 with no privileges and no user interaction required.

Is CVE-2023-4485 in the CISA KEV catalog?

No, not as of 2026-11-27 (catalog version 2026.11.25). FIRST EPSS rates it 0.00924, the 58.71st percentile, in the 2026-11-26 dataset.