CVE-2024-8630 is an SQL injection flaw in the Alisonic Sibylla automatic tank gauge, a device that monitors fuel tank levels. An attacker who reaches its web interface can get complete access to the device database, dump credentials and potentially gain administrator access. NVD scores it 9.8 and CISA 9.4. All versions are affected and Alisonic did not respond to CISA.
Vulnerability summary
CVSS base score
9.8
Critical severity
EPSS score (FIRST)
0.8%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2024-8630 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| Alisonic Sibylla automatic tank gauge | cpe:2.3:o:alisonic:sibylla_firmware:-:*:*:*:*:*:*:* | All versions (CISA ICSA-24-268-02, CVE record); NVD CPE lists the firmware without a version; no fixed version published |
What does this mean for affected devices?
NVD carries CISA's description: "Alisonic Sibylla devices are vulnerable to SQL injection attacks, which could allow complete access to the database." The CVE was published on 2024-09-27 (NVD, CVE record).
What is affected?
CISA's ICSA-24-268-02 of 2024-09-24 lists all versions of Alisonic Sibylla. CISA's risk evaluation says exploitation could let an attacker obtain device information from the database, dump credentials or potentially gain administrator access. CISA lists the Transportation Systems sector with worldwide deployment and credits Pedro Umbelino of Bitsight.
Sibylla was one of six automatic tank gauge (ATG) systems from five vendors that Bitsight TRACE examined. Its write-up of 2024-09-24 lists eleven issues, including CVE-2024-8630 and the ProGauge MAGLINK flaws such as CVE-2024-43423, and argues that ATGs, which watch fuel levels and raise leak and overfill alarms, belong off the internet (Bitsight).
Why do NVD and CISA score it differently?
NVD's Primary score is CVSS v3.1 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). CISA, the CNA, rates availability impact as low and scores 9.4 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L), plus 9.3 in CVSS v4. Both map the flaw to CWE-89, SQL injection. The input handling fix guide covers the parameterised queries that prevent it.
What should owners do?
CISA's advisory says Alisonic did not respond to its coordination attempts and tells users to contact Alisonic and keep their systems up to date. No fixed version is published. Take the gauge's web interface off the internet, put it behind a firewall away from business networks, and allow remote access only through a VPN. Bitsight's main advice is the same: disconnect ATGs from the public internet even where patches exist. The OT security guide for small manufacturers walks through that kind of segmentation for small sites.
CVE-2024-8630 is not in the CISA KEV catalog as of 2026-11-26 (catalog version 2026.11.25, 1,805 entries), and CISA had no reports of public exploitation when it published the advisory. FIRST EPSS gives it 0.00833, the 54.8th percentile, in the 2026-11-25 dataset (CISA KEV, FIRST EPSS).
Evidence
- NVD (read 2026-11-26): status Analyzed; published 2024-09-27; NVD Primary CVSS v3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H; CISA Secondary v3.1 9.4 (A:L) and v4 9.3; CWE-89; CPE alisonic sibylla_firmware without version. — NVD
- CISA ICSA-24-268-02 (2024-09-24), CSAF read 2026-11-26: Alisonic Sibylla all versions; Alisonic did not respond to CISA's coordination attempts; contact Alisonic and keep systems up to date; sector Transportation Systems; credit Pedro Umbelino (Bitsight); no known public exploitation reported. — CISA ICSA-24-268-02
- CVE record (checked 2026-11-26): PUBLISHED, CNA icscert, published 2024-09-27, affected all versions. — CVE.org
- Bitsight blog of 2024-09-24 by Pedro Umbelino: six ATG systems from five vendors; table lists Alisonic Sibylla SQL injection CVE-2024-8630 (9.4) and Maglink LX4 hard-coded credentials CVE-2024-43423; advises disconnecting ATGs from the internet. — Bitsight
- Not in the CISA KEV catalog, catalog version 2026.11.25, 1,805 entries, checked 2026-11-26. — CISA KEV
- EPSS 0.00833, percentile 0.54845, dataset 2026-11-25, read 2026-11-26. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Is there a fix for CVE-2024-8630?
No fixed version is published. CISA's ICSA-24-268-02 says Alisonic did not respond to its coordination attempts and tells users to contact Alisonic and keep systems up to date. Remove the gauge from the internet and segment it.
Which Sibylla versions are affected?
All versions, according to CISA and the CVE record.
What could an attacker do with the database access?
CISA says an attacker could obtain device information, dump credentials or potentially gain administrator access to the gauge.
Is CVE-2024-8630 in the CISA KEV catalog?
No, not as of 2026-11-26 (catalog version 2026.11.25). FIRST EPSS rates it 0.00833 (54.8th percentile) in the 2026-11-25 dataset.