CVE-2023-44487, HTTP/2 Rapid Reset, is a protocol-level denial of service: a client opens and immediately cancels HTTP/2 streams so fast that the server exhausts its resources. NVD scores it 7.5 and CISA KEV lists it. Update every HTTP/2 server, including the web and gRPC servers inside network and industrial devices, to the vendor's fixed release.
Vulnerability summary
CVSS base score
7.5
High severity
EPSS score (FIRST)
94.0%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
Yes
Listed as known exploited
Published
Vulnerability ID: CVE-2023-44487 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| HTTP/2 protocol implementations | cpe:2.3:a:ietf:http:2.0:*:*:*:*:*:*:* | Any HTTP/2 server without stream-reset limits; NVD lists affected versions of Apache Tomcat, Eclipse Jetty, Envoy, Go, gRPC, nginx, F5 BIG-IP and many others |
| Cisco IOS XE (gNMI), IOS XR (gRPC), Nexus 3000/9000 NX-OS (NX-API, gRPC), Secure Web Appliance, Expressway / VCS, IoT Field Network Director | cpe:2.3:o:cisco:ios_xe:*:*:*:*:*:*:*:* | Fixed in IOS XE 17.15.1; IOS XR 7.11.2 and 24.1.1; NX-OS 10.2(7), 10.3(5), 10.4(2) (NX-API) and 10.4(3) (gRPC); Secure Web Appliance 15.1.0; Expressway / VCS X14.3.3; IoT FND 4.11.0 (cisco-sa-http2-reset-d8Kf32vZ) |
| Siemens SINEC NMS, SINEC INS, ST7 ScadaConnect, RUGGEDCOM APE1808 | — | SINEC NMS fixed in V3.0 (SSA-784301); SINEC INS in V1.0 SP2 Update 3 (SSA-915275); ST7 ScadaConnect in V1.1 (SSA-341067); APE1808 via Fortigate NGFW 7.4.3 (SSA-832273) |
| Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (GNU/Linux subsystem) | cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\/dp_mfp_firmware:*:*:*:*:*:*:*:* | >= V3.1.5; Siemens lists no fix, mitigations only (SSA-082556) |
What does this mean for affected devices?
CVE-2023-44487 is a flaw in how HTTP/2 servers handle stream cancellation. The CVE record, published by MITRE on 2023-10-10, says that "the HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023" (NVD, CVE record). NVD's Primary score is 7.5, CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. CISA ADP gives the same score and CWE-400 (uncontrolled resource consumption); NVD records no specific CWE.
CISA's alert of 2023-10-10 says the attack, known as Rapid Reset, "has been exploited in the wild in August 2023 through October 2023", and asks organisations that provide HTTP/2 services to apply patches and consider configuration changes and other mitigations from vendors such as Cloudflare, Google, AWS, NGINX and Microsoft. Because it is a protocol weakness, each implementation needed its own limit on how many streams a client may open and reset.
Which devices are affected?
NVD's CPE configuration runs to dozens of products, from web servers and proxies (Apache Tomcat, Eclipse Jetty, Envoy, Go's HTTP/2 library, gRPC, nginx) to appliances. The device angle is the HTTP/2 or gRPC server embedded in management planes. Cisco's cisco-sa-http2-reset-d8Kf32vZ (v1.11, last updated 2023-12-21) lists, among others, IOS XE with the gNMI server feature (fixed in 17.15.1), IOS XR with the gRPC server (7.11.2 and 24.1.1), Nexus 3000 and 9000 switches with NX-API (10.2(7), 10.3(5), 10.4(2)) or the gRPC agent (10.4(3)), Secure Web Appliance (15.1.0), Expressway and TelePresence VCS (X14.3.3) and IoT Field Network Director (4.11.0). Products not listed are to be considered not vulnerable.
In industrial products, Siemens ProductCERT fixed SINEC NMS in V3.0 (SSA-784301), SINEC INS in V1.0 SP2 Update 3 (SSA-915275), ST7 ScadaConnect in V1.1 (SSA-341067) and RUGGEDCOM APE1808 through Fortigate NGFW 7.4.3 (SSA-832273). For the GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP from V3.1.5, SSA-082556 says "Currently no fix is available" and recommends limiting shell access to trusted personnel and running only trusted applications. Not every implementation counted itself affected: an nginx maintainer wrote that nginx's default per-connection request limit already protects it, while adding a per-iteration stream limit anyway.
How do you fix CVE-2023-44487?
Update each HTTP/2 server to its vendor's fixed release; on network and industrial devices that means the firmware or software versions above. Where an update is not available, turn off HTTP/2 or gRPC management features that are not needed, keep management interfaces off untrusted networks, as CISA's internet-exposed management interface guidance describes, and put internet-facing HTTP/2 services behind a DDoS-protected proxy. Our input-handling fix guide covers per-client limits for embedded servers. Other KEV-listed network denial-of-service flaws are the SLP amplification CVE-2023-29552 and the NTP monlist flaw CVE-2013-5211.
Is CVE-2023-44487 exploited?
Yes. CISA added it to the KEV catalog on 2023-10-10 as "HTTP/2 Rapid Reset Attack Vulnerability", with a due date of 2023-10-31 and the required action to apply mitigations per vendor instructions, follow BOD 22-01 guidance for cloud services, or discontinue use if mitigations are unavailable. Known ransomware campaign use is marked Unknown. It is listed as of 2026-11-26 (catalog version 2026.11.25). FIRST EPSS gives it 0.93995, the 99.90th percentile, in the 2026-11-25 dataset (CISA KEV, FIRST EPSS). Our KEV and EPSS prioritisation guide explains how to rank it.
Evidence
- NVD: [email protected] Primary CVSS 3.1 7.5 AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H; CISA ADP 7.5 with CWE-400; NVD CWE noinfo; CPEs incl. Apache Tomcat, Jetty, Envoy, Go, gRPC, nginx, F5 BIG-IP, Cisco IOS XE/IOS XR/NX-OS, Siemens SINEC INS/NMS and S7-1500 MFP; published 2023-10-10; read 2026-11-26. — NVD
- CVE record (CNA MITRE): PUBLISHED 2023-10-10. — CVE.org
- CISA alert 2023-10-10: Rapid Reset exploited in the wild August through October 2023; apply patches and consider configuration changes; vendor guidance from Cloudflare, Google, AWS, NGINX, Microsoft. — CISA
- Cisco cisco-sa-http2-reset-d8Kf32vZ v1.11 (first published 2023-10-16, updated 2023-12-21): IOS XE gNMI 17.15.1; IOS XR gRPC 7.11.2/24.1.1; Nexus 3000/9000 NX-API 10.2(7)/10.3(5)/10.4(2), gRPC agent 10.4(3); Secure Web Appliance 15.1.0; Expressway/VCS X14.3.3; IoT FND 4.11.0; unlisted products considered not vulnerable. — Cisco
- Siemens CSAF: SSA-784301 (2024-08-13) SINEC NMS update to V3.0; SSA-915275 (2024-11-12) SINEC INS V1.0 SP2 Update 3; SSA-341067 (2024-06-11) ST7 ScadaConnect V1.1; SSA-832273 RUGGEDCOM APE1808 Fortigate NGFW 7.4.3; SSA-082556 S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.5 'Currently no fix is available', mitigations limit shell access and trusted applications. — Siemens ProductCERT
- nginx-devel (Maxim Dounin, 2023-10-10): per-iteration stream handling limit patch; nginx not considered affected in default configuration thanks to keepalive_requests. — nginx-devel mailing list
- CISA KEV catalog 2026.11.25: dateAdded 2023-10-10, due 2023-10-31, knownRansomwareCampaignUse Unknown, CWE-400, required action apply mitigations per vendor instructions / BOD 22-01 / discontinue; checked 2026-11-26. — CISA KEV
- EPSS 0.93995, percentile 0.99902, dataset 2026-11-25, read 2026-11-26. — FIRST EPSS

Related advisories
Sources
- NVD
- CVE.org record CVE-2023-44487 (CNA: MITRE)
- CISA: HTTP/2 Rapid Reset Vulnerability, CVE-2023-44487
- Cisco cisco-sa-http2-reset-d8Kf32vZ: HTTP/2 Rapid Reset Attack Affecting Cisco Products
- Siemens SSA-784301: Multiple Vulnerabilities in SINEC NMS Before V3.0
- Siemens SSA-915275: Multiple Vulnerabilities in SINEC INS Before V1.0 SP2 Update 3
- Siemens SSA-341067: Multiple vulnerabilities in third-party components in ST7 ScadaConnect before V1.1
- Siemens SSA-832273: Multiple Vulnerabilities in Fortigate NGFW Before V7.4.3 on RUGGEDCOM APE1808 Devices
- Siemens SSA-082556: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1.5
- nginx-devel: HTTP/2 per-iteration stream handling limit
- CISA KEV
- FIRST EPSS
Frequently asked questions
Which Cisco devices are affected by HTTP/2 Rapid Reset?
Cisco lists IOS XE with the gNMI server (fixed in 17.15.1), IOS XR with the gRPC server (7.11.2, 24.1.1), Nexus 3000 and 9000 NX-OS with NX-API or the gRPC agent, Secure Web Appliance, Expressway and TelePresence VCS, IoT Field Network Director and other products; unlisted products are considered not vulnerable (per cisco-sa-http2-reset-d8Kf32vZ).
Which Siemens industrial products are affected by CVE-2023-44487?
Siemens fixed SINEC NMS in V3.0, SINEC INS in V1.0 SP2 Update 3, ST7 ScadaConnect in V1.1 and RUGGEDCOM APE1808 through Fortigate NGFW 7.4.3. For the S7-1500 CPU 1518(F)-4 PN/DP MFP GNU/Linux subsystem from V3.1.5 it lists no fix, only mitigations (per Siemens SSA-784301, SSA-915275, SSA-341067, SSA-832273 and SSA-082556).
Is CVE-2023-44487 a bug in one product?
No. It is a weakness in how the HTTP/2 protocol handles stream cancellation, so each HTTP/2 server implementation had to add its own limits; NVD lists dozens of affected products and CISA asks HTTP/2 service operators to apply vendor patches and mitigations (per the CVE record, NVD and CISA's alert of 2023-10-10).
Is CVE-2023-44487 exploited in the wild?
Yes. CISA added it to the KEV catalog on 2023-10-10 and it is listed as of 2026-11-26 (catalog version 2026.11.25), with ransomware use marked Unknown. FIRST EPSS gives it 0.93995, the 99.90th percentile, in the 2026-11-25 dataset (per CISA KEV and FIRST EPSS).
Questions about this page?