CVE-2023-30799 is a privilege escalation in MikroTik RouterOS: an attacker who already holds an administrator login can raise it to "super-admin" over Winbox or the web interface and then run arbitrary code on the operating system under RouterOS. NVD scores it 7.2 and VulnCheck 9.1. MikroTik says RouterOS 6.49.7, 7.7 and newer fix it.
Vulnerability summary
CVSS base score
7.2
High severity
EPSS score (FIRST)
1.1%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2023-30799 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| MikroTik RouterOS 6 (stable release channel) | cpe:2.3:o:mikrotik:routeros:*:*:*:*:-:*:*:* | Before 6.49.7 (CVE record); NVD CPE: 6.34 up to, excluding, 6.49.7; fixed in 6.49.7 and newer (MikroTik) |
| MikroTik RouterOS 6 (long-term release channel) | cpe:2.3:o:mikrotik:routeros:*:*:*:*:ltr:*:*:* | Through 6.48.6 (CVE record and VulnCheck); NVD CPE reads up to and including 6.48.7; move to 6.49.7 or newer |
| MikroTik RouterOS 7 | — | MikroTik names v7.7 and newer as fixed; NVD and the CVE record list no RouterOS 7 range |
What does this mean for affected devices?
NVD's description, from VulnCheck as CNA: "MikroTik RouterOS stable before 6.49.7 and long-term through 6.48.6 are vulnerable to a privilege escalation issue. A remote and authenticated attacker can escalate privileges from admin to super-admin on the Winbox or HTTP interface. The attacker can abuse this vulnerability to execute arbitrary code on the system" (NVD, CVE record). It is one of the older RouterOS flaws listed in the MikroTik RouterOS and DrayTek Vigor vulnerability guide.
Why do the scores differ?
NVD's Primary score is CVSS v3.1 7.2 (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H). VulnCheck, the CNA, scores 9.1 (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H) because it treats the escape from RouterOS into the underlying system as a scope change. Both require high privileges: the attacker must already be an administrator. VulnCheck maps the flaw to CWE-269, improper privilege management; NVD records NVD-CWE-noinfo. VulnCheck's advisory of 2023-07-19 says the flaw is in its own VulnCheck KEV list.
What does MikroTik say?
MikroTik's notice on CVE-2023-30799 (2023-07-27) describes a policy elevation issue: an administrator with "policy" rights can send crafted configuration commands that RouterOS components exchange internally and would normally reject from a user, which can be a stepping stone to running code on the system. MikroTik stresses that the attacker needs a known username and password and a reachable management interface, and that a full administrator can already take over a router in other ways. It says the issue is fixed in v7.7, v6.49.7 and newer. Its suggested actions: do not give administrative access to untrusted users, firewall the router against brute-force logins, use the RouterOS device-mode feature to lock critical functions, and keep RouterOS updated.
One version detail differs between sources. The CVE record and VulnCheck say long-term "through 6.48.6"; NVD's CPE configuration reads long-term "up to and including 6.48.7". Either way, the fix is to move to 6.49.7 or newer.
Is CVE-2023-30799 exploited?
It is not in the CISA KEV catalog as of 2026-11-28 (catalog version 2026.11.27, CISA KEV). FIRST EPSS gives 0.01079, the 64.67th percentile, in the 2026-11-27 dataset (FIRST EPSS). Because it starts from a valid admin login, it chains with credential theft such as the exploited Winbox file read CVE-2018-14847; a later RouterOS privilege escalation is CVE-2026-86060. See KEV and EPSS vulnerability prioritization for weighing a post-authentication flaw like this one.


Evidence
- NVD (read 2026-11-28): status Modified, published 2023-07-19; NVD Primary CVSS v3.1 7.2 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H; VulnCheck Secondary 9.1 with S:C; CWE-269 (VulnCheck), NVD-CWE-noinfo (NVD); CPE routeros ltr up to and including 6.48.7, stable 6.34 to before 6.49.7. — NVD
- CVE record: CNA VulnCheck, PUBLISHED 2023-07-19; RouterOS affected below 6.49.7 and up to and including 6.48.6; CVSS 3.1 9.1. — CVE Services
- MikroTik notice 2023-07-27: policy elevation by administrator with policy permission via crafted internal configuration commands; needs administrative credentials and reachable interface; fixed in v7.7, v6.49.7 and newer; suggested actions (trusted admins only, brute-force firewall, device-mode, keep updated). — MikroTik
- VulnCheck advisory 2023-07-19: severity critical, CVSS 9.1, CWE-269, RouterOS < 6.49.7 and <= 6.48.6; listed in VulnCheck KEV. — VulnCheck
- Not in KEV catalog version 2026.11.27, checked 2026-11-28. — CISA KEV
- EPSS 0.01079, percentile 0.64673, dataset 2026-11-27, read 2026-11-28. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which RouterOS versions fix CVE-2023-30799?
MikroTik says v6.49.7, v7.7 and newer releases fix it. Affected are stable builds before 6.49.7 and long-term builds through 6.48.6 (per MikroTik and the CVE record).
Can CVE-2023-30799 be exploited without a password?
No. The attacker needs an administrator account and a reachable Winbox or web interface; the flaw lets that admin become "super-admin" and run code on the underlying system (per NVD and MikroTik).
Why does VulnCheck score CVE-2023-30799 9.1 while NVD scores 7.2?
VulnCheck marks the scope as changed because the attacker escapes RouterOS into the underlying operating system; NVD keeps the scope unchanged. All other CVSS v3.1 metrics are the same (per NVD).
Is CVE-2023-30799 in the CISA KEV catalog?
No, not as of 2026-11-28 (catalog 2026.11.27), although VulnCheck lists it in its own KEV list. FIRST EPSS gives 0.01079 (64.67th percentile) in the 2026-11-27 dataset (per CISA KEV, VulnCheck and FIRST EPSS).
Questions about this page?