Security Advisory

CVE-2019-3929: Crestron AirMedia AM-100/101 Root RCE

Last updated:
  • CVE-2019-3929

CVE-2019-3929 is an unauthenticated command injection in the web server of Crestron AirMedia AM-100 and AM-101 wireless presentation gateways and other presentation boxes built on the same code, including Barco wePresent and Extron ShareLink. A remote attacker can run commands as root. NVD scores it 9.8 and CISA KEV lists it; Crestron fixes it in AM-100/101 firmware 1.7.1.7_2.8.0.27.

Vulnerability summary

CVSS base score

9.8

Critical severity

EPSS score (FIRST)

99.0%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

Yes

Listed as known exploited

Published

Vulnerability ID: CVE-2019-3929 · Source: NVD Primary

Affected components

ComponentCPEVersion range
Crestron AirMedia AM-100 / AM-101 wireless presentation gatewayscpe:2.3:o:crestron:am-100_firmware:1.6.0.2:*:*:*:*:*:*:*AM-100 1.6.0.2 and AM-101 2.7.0.1/2.7.0.2; fixed in AM-100/101 firmware 1.7.1.7_2.8.0.27 (Crestron)
Barco wePresent WiPG-1000P and WiPG-1600Wcpe:2.3:o:barco:wepresent_wipg-1600w_firmware:*:*:*:*:*:*:*:*WiPG-1000P 2.3.0.10; WiPG-1600W before 2.4.1.19 (NVD)
Extron ShareLink 200/250, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Black Box HD WPS, InFocus LiteShow3/LiteShow4—Firmware versions named in NVD (e.g. ShareLink 2.0.3.4, WIPS710 1.1.0.7, PN-L703WA 1.4.2.3, LiteShow4 2.0.0.7)

What does this mean for affected devices?

NVD lists the "Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4", Teq AV IT WIPS710 1.1.0.7, SHARP PN-L703WA 1.4.2.3, Optoma WPS-Pro 1.0.0.5, Black Box HD WPS 1.0.0.5, InFocus LiteShow3 1.0.16 and LiteShow4 2.0.0.7 as "vulnerable to command injection" through a file-transfer HTTP endpoint, letting "A remote, unauthenticated attacker" run operating system commands as root. NVD's Primary score is CVSS v3.1 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) with NVD CVSS v2 10.0 and CWE-78. Tenable, the CNA, published no CVSS in the CVE record and tagged the weakness CWE-79; CISA KEV repeats CWE-79, but the described flaw is command injection (NVD, CVE record).

Which devices are affected and what is the fix?

Tenable's research advisory TRA-2019-20 found the issue on a Crestron AM-100 and traced it to a code base shared by the other brands listed above; it says the flaw "appears to affect all known devices". Crestron's security advisories page (entry "AM-100 and AM-101 Vulnerabilities", 2021-07-27) says the flaw "has been resolved with the firmware release AM-100/101 v.1.7.1.7_2.8.0.27", made that firmware publicly available, and asks anyone who needs help to contact Crestron True Blue Support. Crestron adds that the issues in that report affect only the AM-100 and AM-101; its other second-generation AirMedia devices are not affected. NVD names Barco wePresent WiPG-1600W 2.4.1.19 as the first fixed release for that model. Tenable's disclosure timeline records that Black Box said it no longer offers its HD WPS product and that the last firmware it received from the OEM was 1.0.0.5; for the other OEM brands, check each vendor's firmware page, since KEV's required action is to apply updates per vendor instructions.

Is CVE-2019-3929 exploited?

Yes. CISA added it to KEV on 2022-04-15 with the required action "Apply updates per vendor instructions." (due 2022-05-06; known ransomware campaign use: Unknown); it is listed as of 2026-11-26 in catalog version 2026.11.25 (CISA KEV). FIRST EPSS gives 0.98952, the 99.96th percentile, in the 2026-11-25 dataset (FIRST EPSS).

Keep the web and management ports of presentation gateways off the internet as CISA BOD 23-02 asks. Other unauthenticated root command injections in device web servers on KEV include Sunhillo SureLine CVE-2021-36380 and D-Link DIR-820L CVE-2023-25280; the class fix is in how to fix command injection in embedded firmware.

How to fix this class of issueThis advisory's weakness class is Command injection. Our practical guide covers how to detect, fix, verify and disclose it: How to fix command injection in embedded firmware.

Evidence

  • NVD: Analyzed; Crestron AM-100 1.6.0.2, AM-101 2.7.0.1, Barco WiPG-1000P 2.3.0.10, WiPG-1600W before 2.4.1.19, Extron ShareLink 200/250 2.0.3.4, Teq AV IT WIPS710 1.1.0.7, SHARP PN-L703WA 1.4.2.3, Optoma WPS-Pro 1.0.0.5, Blackbox HD WPS 1.0.0.5, InFocus LiteShow3 1.0.16, LiteShow4 2.0.0.7; unauthenticated root command injection; NVD Primary CVSS v3.1 9.8, v2 10.0; NVD CWE-78, Tenable CWE-79; published 2019-04-30; read 2026-11-26. — NVD
  • Crestron security advisories page, entry 2021-07-27 "AM-100 and AM-101 Vulnerabilities": CVE-2019-3929 resolved with firmware AM-100/101 v.1.7.1.7_2.8.0.27; firmware made publicly available; contact True Blue Support; only AM-100 and AM-101 affected, other second-generation AirMedia devices not affected. — Crestron
  • Tenable TRA-2019-20: found on Crestron AM-100, shared code base with Barco wePresent, Extron ShareLink, InFocus LiteShow, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS; CVE-2019-3929 appears to affect all known devices; timeline: Black Box no longer offers the product, last OEM firmware 1.0.0.5. — Tenable
  • KEV catalog 2026.11.25: dateAdded 2022-04-15, due 2022-05-06, required action "Apply updates per vendor instructions.", knownRansomwareCampaignUse Unknown, CWE-79; checked 2026-11-26. — CISA KEV
  • EPSS 0.98952, percentile 0.99960, dataset 2026-11-25, read 2026-11-26. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. Crestron security advisories (AM-100 and AM-101 vulnerabilities)
  3. Tenable research advisory TRA-2019-20
  4. CVE.org record CVE-2019-3929 (CNA: Tenable)
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Which Crestron firmware fixes CVE-2019-3929?

AM-100/101 firmware 1.7.1.7_2.8.0.27, per Crestron's security advisories page. Crestron says other second-generation AirMedia devices are not affected.

Are non-Crestron devices affected by CVE-2019-3929?

Yes. NVD and Tenable list Barco wePresent WiPG-1000P and WiPG-1600W (fixed in 2.4.1.19), Extron ShareLink 200/250, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Black Box HD WPS and InFocus LiteShow3/LiteShow4, which share the same code base.

Why does CISA KEV list CWE-79 for CVE-2019-3929?

KEV repeats the CWE-79 tag from Tenable's CVE record. NVD's own analysis assigns CWE-78 (OS command injection), which matches the description of root command execution.

Is CVE-2019-3929 exploited?

CISA added it to KEV on 2022-04-15 with known ransomware use Unknown. FIRST EPSS gives 0.98952 (99.96th percentile) in the 2026-11-25 dataset, as of 2026-11-26.