Security Advisory

CVE-2019-13923: Siemens IE/WSN-PA Link Gateway XSS

Last updated:
  • CVE-2019-13923

CVE-2019-13923 is a cross-site scripting flaw in the configuration web server of the Siemens IE/WSN-PA Link, the gateway between a WirelessHART network and wired Ethernet. A logged-in user who opens a malicious link runs the attacker's script in the gateway session. All versions are affected and Siemens lists a workaround only. NVD scores it 9.6, Siemens 7.5.

Vulnerability summary

CVSS base score

9.6

Critical severity

EPSS score (FIRST)

1.1%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2019-13923 · Source: NVD

Affected components

ComponentCPEVersion range
Siemens IE/WSN-PA Link WirelessHART Gateway firmware (configuration web server)cpe:2.3:o:siemens:ie\/wsn-pa_link_wirelesshart_gateway_firmware:*:*:*:*:*:*:*:*All versions (Siemens SSA-191683 V1.0, CISA ICSA-19-253-04); no fixed version listed

What does this mean for affected devices?

Siemens ProductCERT's SSA-191683, published 2019-09-10, describes the IE/WSN-PA Link as "a gateway between a WirelessHART network and wired Ethernet network" and says its "integrated configuration web server ... could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link." User interaction is required, and "the user must be logged into the web interface in order for the exploitation to succeed." Siemens credits William Knowles for coordinated disclosure, and CISA republished the advisory as ICSA-19-253-04, with a machine-readable CSAF copy.

Why do NVD and Siemens score it so differently?

NVD's Primary score is CVSS v3.1 9.6 (critical), vector CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H, with CWE-79 (NVD). Siemens scores it CVSS v3.0 7.5 (high), vector CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C, and classes it as CWE-80, basic XSS. The difference is attack complexity (NVD low, Siemens high, since the victim must already be logged in) and scope (NVD changed, Siemens unchanged). Both agree the impact on a successful attack is high: script running in an administrator's session can change gateway settings through the same web interface.

Which versions are fixed?

None. SSA-191683 lists "All versions" as affected, and its remediation is the workaround section; the advisory text is still version 1.0 of 2019-09-10 (checked 2026-11-17). The one product-specific mitigation Siemens gives is: "Only access links from trusted sources in the browser you use to configure the IE/WSN-PA Link." In practice that means a dedicated browser or jump host for gateway administration that is not used for mail or general browsing, logging out of the gateway after each change, and restricting which hosts can reach the web interface, in line with Siemens' general advice to protect network access to the device.

Our HART and WirelessHART security guide lists this flaw with the other gateway web-interface bugs, such as the Pepperl+Fuchs path traversal CVE-2018-16059. For the weakness class, see the input handling fix guide and another device-web-interface XSS, CVE-2020-6973 in a Digi terminal server.

CVE-2019-13923 is not in the CISA KEV catalog as of 2026-11-17 (catalog version 2026.11.13). FIRST EPSS gives it 0.0112, the 67th percentile, in the 2026-11-16 dataset (CISA KEV, FIRST EPSS). Siemens reported no public exploitation when it published the advisory.

How to fix this class of issueThis advisory's weakness class is Cross-site scripting (XSS). Our practical guide covers how to detect, fix, verify and disclose it: How to fix SQL injection, XSS, resource exhaustion and deserialization flaws in embedded firmware.

Evidence

  • NVD Primary CVSS v3.1 9.6 AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H; v2 4.3; CWE-79 (NVD), CWE-80 (Siemens); CPE ie/wsn-pa_link_wirelesshart_gateway_firmware all versions; published 2019-09-13. — NVD
  • SSA-191683 V1.0 published and last updated 2019-09-10: IE/WSN-PA Link WirelessHART Gateway all versions; XSS in integrated configuration web server; user interaction and logged-in user required; CVSS v3.0 7.5 AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C; workaround: only access links from trusted sources in the browser used to configure the IE/WSN-PA Link; product is a gateway between a WirelessHART network and wired Ethernet; thanks William Knowles. — Siemens ProductCERT SSA-191683
  • CSAF ICSA-19-253-04 (2019-09-10), converted from Siemens ProductCERT's advisory: IE/WSN-PA Link WirelessHART Gateway vers:all; CWE-80; CVSS v3.0 7.5. — CISA ICSA-19-253-04 (CSAF)
  • Not in the CISA KEV catalog, version 2026.11.13, checked 2026-11-17. — CISA KEV
  • EPSS 0.0112, percentile 0.66702, dataset 2026-11-16. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. Siemens ProductCERT SSA-191683: Cross-Site Scripting Vulnerability in IE/WSN-PA Link WirelessHART Gateway
  3. CISA ICS Advisory ICSA-19-253-04: Siemens IE/WSN-PA Link WirelessHART Gateway
  4. CISA CSAF: ICSA-19-253-04 (machine-readable advisory)
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Is there a firmware fix for CVE-2019-13923?

No fixed version is listed. Siemens SSA-191683 names all versions of the IE/WSN-PA Link WirelessHART Gateway as affected and gives a workaround: only open links from trusted sources in the browser used to configure the gateway (per Siemens SSA-191683, checked 2026-11-17).

Why is CVE-2019-13923 rated 9.6 by NVD but 7.5 by Siemens?

NVD rates attack complexity low and scope changed; Siemens rates complexity high, because the victim must be logged in to the web interface, and scope unchanged. Both rate confidentiality, integrity and availability impact high (per NVD and Siemens SSA-191683).

Does CVE-2019-13923 break WirelessHART encryption?

No. It is a cross-site scripting flaw in the gateway's configuration web server on the Ethernet side; the attacker acts through a logged-in administrator's browser, not through the WirelessHART radio network (per Siemens SSA-191683).

Is CVE-2019-13923 in the CISA KEV catalog?

No, not as of 2026-11-17 (catalog version 2026.11.13). FIRST EPSS gives it 0.0112, the 67th percentile, in the 2026-11-16 dataset (per CISA KEV and FIRST EPSS).