Security Advisory

CVE-2019-10979: SICK MSC800 Hard-Coded Password

Last updated:
  • CVE-2019-10979

CVE-2019-10979 is a hard-coded customer account password in SICK MSC800 firmware before version 4.0. A low-skilled remote attacker who can reach the device could use it to change settings or disrupt the device. NVD, SICK and CISA all score it 9.8. SICK fixed it in firmware V4.0, which also lets owners set their own passwords.

Vulnerability summary

CVSS base score

9.8

Critical severity

EPSS score (FIRST)

3.4%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2019-10979 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
SICK MSC800cpe:2.3:o:sick:msc800_firmware:*:*:*:*:*:*:*:*Firmware before 4.0 (NVD, SICK SCA-2019-0001, CISA ICSA-19-178-04); fixed in V4.0, available from the responsible SICK contact

What does this mean for affected devices?

CVE-2019-10979 is a use of hard-coded credentials (CWE-798) in the SICK MSC800. The CVE record, published by CISA on 2019-07-01, says that in all MSC800 versions prior to 4.0, "the affected firmware versions contain a hard-coded customer account password" (NVD, CVE record). NVD's Primary score is 9.8, CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, with CWE-798. Here the scorers agree: CISA's advisory and SICK's own advisory, which uses CVSS 3.1, both give 9.8 with the same base metrics.

Which SICK devices are affected?

SICK's PSIRT advisory SCA-2019-0001, first released on 2019-06-21 and last revised on 2025-07-30 (only the link to SICK's operating guidelines changed), lists MSC800 firmware below 4.0 as affected and 4.0 as fixed. SICK says the hard-coded credentials "potentially allow low-skilled unauthorized remote attackers to reconfigure settings and /or disrupt the functionality of the device". CISA's ICSA-19-178-04, released on 2019-06-27, gives the same version boundary for the Critical Manufacturing sector, worldwide. Tri Quach of Amazon's Customer Fulfillment Technology Security group reported the flaw. SICK's advisory feed also lists later MSC800 advisories, SCA-2022-0006 and SCA-2024-0002, for separate issues, so check that a unit is on SICK's current firmware rather than only V4.0.

How do you fix CVE-2019-10979?

Update to firmware V4.0 or later. SICK says the update lets customers change the default customer passwords and optionally disable device configuration over chosen network interfaces, which it recommends especially in critical infrastructure; after updating, set new passwords and switch off configuration on any interface that does not need it. The firmware and installation procedure come from the responsible SICK customer contact rather than a public download. Until the update is installed, SICK advises minimising the device's network exposure, restricting network access and following its cybersecurity operating guidelines, listed on the SICK PSIRT page. The hard-coded credentials fix guide covers how makers avoid fixed accounts, and the OT security guide for small manufacturers covers segmenting plant devices. Other hard-coded credential pages for industrial devices include the RuggedCom ROS factory account CVE-2012-1803 and the Yokogawa STARDOM password CVE-2018-10592.

Is CVE-2019-10979 exploited?

CVE-2019-10979 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). SICK and CISA reported no known public exploits targeting it at release. FIRST EPSS gives it 0.03378, the 89.54th percentile, in the 2026-11-26 dataset (CISA KEV, FIRST EPSS).

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is Hard-coded credentials. Our practical guide covers how to detect, fix, verify and disclose it: How to fix hard-coded credentials in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • NVD (read 2026-11-27): status Modified, published 2019-07-01; [email protected] Primary CVSS 3.0 9.8 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, CVSS 2.0 7.5; CWE-798; CPE sick msc800_firmware < 4.0. — NVD
  • SICK SCA-2019-0001 (initial 2019-06-21, rev 3 2025-07-30): MSC800 firmware < 4.0 affected, 4.0 fixed; CWE-798; CVSS 3.1 9.8; V4.0 allows changing default customer passwords and disabling device configuration over chosen network interfaces; update from the responsible SICK contact; no known public exploits. — SICK PSIRT (CSAF)
  • CISA ICSA-19-178-04 (2019-06-27): MSC800 < 4.0; CWE-798; CVSS v3 9.8; upgrade to v4.0; reported by Tri Quach of Amazon's Customer Fulfillment Technology Security group; sector Critical Manufacturing. — CISA CSAF
  • SICK CSAF feed lists MSC800 advisories SCA-2019-0001, SCA-2022-0006 and SCA-2024-0002. — SICK PSIRT
  • CISA KEV catalog 2026.11.25 (1,805 entries): not listed, checked 2026-11-27. — CISA KEV
  • EPSS 0.03378, percentile 0.89540, dataset 2026-11-26. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. SICK SCA-2019-0001: MSC800 affected by hard-coded credentials vulnerability (CSAF)
  3. SICK PSIRT
  4. CISA ICSA-19-178-04: SICK MSC800 (CSAF)
  5. CISA ICSA-19-178-04 advisory page
  6. CVE.org record CVE-2019-10979
  7. CISA KEV
  8. FIRST EPSS

Frequently asked questions

Which SICK MSC800 versions are affected by CVE-2019-10979?

All MSC800 firmware versions before 4.0 (SICK SCA-2019-0001, CISA ICSA-19-178-04, NVD).

How is CVE-2019-10979 fixed?

Install MSC800 firmware V4.0 or later, obtained through the responsible SICK customer contact, then change the default customer passwords and disable configuration on network interfaces that do not need it, which V4.0 makes possible.

Do NVD, SICK and CISA agree on the severity of CVE-2019-10979?

Yes. NVD (CVSS 3.0), CISA (CVSS 3.0) and SICK (CVSS 3.1) all score it 9.8 with network access, no privileges and high impact on confidentiality, integrity and availability.

Is CVE-2019-10979 exploited in the wild?

It is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS rates it 0.03378, the 89.54th percentile, in the 2026-11-26 dataset.