CVE-2018-19879 is a missing brute-force protection on the LuCI web login of Teltonika RUT9XX cellular routers such as the RUT950. An anonymous attacker can try passwords without limit until one works. NVD scores it 9.8, the CNA MITRE 7.1. The CVE record names R_00.05.00.5, released on 2018-05-30, as the first fixed firmware.
Vulnerability summary
CVSS base score
9.8
Critical severity
EPSS score (FIRST)
1.3%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2018-19879 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| Teltonika RUT950 and other RUT9XX routers (RUT9XX firmware, legacy WebUI) | cpe:2.3:o:teltonika:rut950_firmware:r_31.04.89:*:*:*:*:*:*:* | R_31.04.89 before R_00.05.00.5 per the CVE description; NVD's CPE lists only rut950_firmware r_31.04.89. Teltonika's legacy changelog dates RUT9XX_R_00.05.00.5 to 2018-05-30 without naming the fix |
What does this mean for affected devices?
NVD carries MITRE's description: "An issue was discovered in /cgi-bin/luci on Teltonika RTU9XX (e.g., RUT950) R_31.04.89 before R_00.05.00.5 devices. The authentication functionality is not protected from automated tools used to make login attempts to the application. An anonymous attacker has the ability to make unlimited login attempts with an automated tool." The record was published on 2019-03-28 (NVD, CVE record). "RTU9XX" in the record means the RUT9XX router family. The weakness is CWE-307, improper restriction of excessive authentication attempts.
What does the flaw allow?
The LuCI web login at /cgi-bin/luci accepted unlimited password guesses with no lockout or delay. An attacker who can reach the web interface can run a password list against the admin account until a guess works, and a correct admin password gives full control of the router: routing, firewall, VPN and the devices behind it. The risk depends on password strength and on whether the web interface is reachable from the WAN or mobile side.
Which devices and firmware are affected?
NVD's CPE configuration covers only the RUT950 on firmware R_31.04.89, the version the finder tested; the description names the whole RUT9XX family and R_00.05.00.5 as the first fixed release. Teltonika's RUT950 legacy firmware changelog dates RUT9XX_R_00.05.00.5 to 2018-05-30. That entry lists "Added forced password change" and "New firmware versioning system" and does not mention login attempt limits, so the changelog does not confirm the fix by name. The RUT955 and RUT900 legacy changelogs carry the same entry. The legacy WebUI line ends at RUT9XX_R_00.06.09.5 (2023-05-19), which fixed CVE-2023-32349; the useful target is the current firmware for the model.
How severe is CVE-2018-19879?
The two scores differ. NVD's Primary score is CVSS v3.0 9.8 (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H), with a v2 score of 5.0. The CNA, MITRE, scores CVSS v3.0 7.1 (CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L), treating the attacker as adjacent and the impact as low. The NVD figure assumes the login is reachable over the network and that a guessed admin password gives full control.
CVE-2018-19879 is not in the CISA KEV catalog as of 2026-11-23 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.01257, the 70.3rd percentile, in the 2026-11-22 dataset (CISA KEV, FIRST EPSS).
What should owners of old RUT9XX routers do?
Update to the current firmware for the model, set a long unique admin password, and keep the web interface and SSH off the WAN; reach the router over a VPN instead. Check the router's logs for repeated failed logins if it was exposed. The same lack of login throttling appears on other industrial cellular routers, such as the Advantech flaw CVE-2019-18235 and the Hirschmann switch web login CVE-2018-5469. RUT9XX routers of the same age also carry the unauthenticated command injection CVE-2018-17532. See the Teltonika industrial cellular router guide and the authentication bypass fix guide.
Evidence
- NVD (read 2026-11-23): status Modified; published 2019-03-28; NVD Primary CVSS v3.0 9.8 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, v2 5.0 AV:N/AC:L/Au:N/C:P/I:N/A:N; MITRE Secondary CVSS v3.0 7.1 CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L; CWE-307 (Primary); CPE teltonika rut950_firmware r_31.04.89 only; references Teltonika RUT9xx firmware wiki and a Triad Security PDF. — NVD
- CVE record (read 2026-11-23): state PUBLISHED, CNA MITRE, published 2019-03-28; CNA CVSS v3.0 7.1. — CVE.org
- Teltonika RUT950 legacy WebUI firmware changelog (oldid 107667, read 2026-11-23): 'RUT9XX_R_00.05.00.5 | 2018.05.30 New features: Added forced password change New firmware versioning system'; no login attempt limit entry; latest legacy RUT9XX_R_00.06.09.5 (2023.05.19). RUT955 and RUT900 legacy changelogs carry the same entries. — Teltonika Networks wiki
- Not in the CISA KEV catalog, catalog version 2026.11.20 (1,790 entries), checked 2026-11-23. — CISA KEV
- EPSS 0.01257, percentile 0.70298, dataset 2026-11-22, read 2026-11-23. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which firmware fixes CVE-2018-19879?
The CVE record names R_00.05.00.5 as the first fixed release. Teltonika's legacy changelog dates RUT9XX_R_00.05.00.5 to 2018-05-30 and lists a forced password change, but no entry about login attempt limits. Use the current firmware for the model.
Why are there two different scores?
NVD's Primary CVSS v3.0 score is 9.8, assuming network access and full impact from a guessed admin password. MITRE, the CNA, scores 7.1 with an adjacent attack vector and low impacts.
Which routers are affected?
The description names the RUT9XX family, for example the RUT950, from R_31.04.89 before R_00.05.00.5. NVD's CPE configuration lists only the RUT950 on R_31.04.89.
Is CVE-2018-19879 in the CISA KEV catalog?
No, not as of 2026-11-23 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS rates it 0.01257 (70.3rd percentile) in the 2026-11-22 dataset.
Questions about this page?