Security Advisory

CVE-2018-0156: Cisco Smart Install Reload DoS

Last updated:
  • CVE-2018-0156

CVE-2018-0156 is a denial-of-service flaw in the Smart Install client of Cisco IOS and IOS XE switches. One crafted packet to TCP port 4786 from an unauthenticated remote sender reloads the switch. NVD scores it 7.5 and CISA KEV lists it. Upgrade, and turn Smart Install off with no vstack where you do not need it.

Vulnerability summary

CVSS base score

7.5

High severity

EPSS score (FIRST)

9.4%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

Yes

Listed as known exploited

Published

Vulnerability ID: CVE-2018-0156 · Source: NVD

Affected components

ComponentCPEVersion range
Cisco IOS and IOS XE Software, Smart Install client switchescpe:2.3:o:cisco:ios:15.2\(2\)e4:*:*:*:*:*:*:*199 affected releases in Cisco's CSAF (134 IOS in trains 12.2EX to 15.7M, 65 IOS XE 3.2SE to 16.6); first fixed release per the Cisco IOS Software Checker; Catalyst 6500 and 6800 found not vulnerable. NVD's CPE configuration names only 15.2(2)E4 and 15.2(2a)JA
Rockwell Automation Allen-Bradley Stratix 5400, 5410, 5700, 8000 and ArmorStratix 5700—15.2(6)E0a and earlier; fixed in FRN 15.2(6)E1 or later (ICSA-18-107-04)

What does this mean for affected devices?

NVD describes it: "The vulnerability is due to improper validation of packet data. An attacker could exploit this vulnerability by sending a crafted packet to an affected device on TCP port 4786. Only Smart Install client switches are affected." NVD's Primary score is CVSS v3.1 7.5 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H) and NVD CVSS v2 7.8, with CWE-20; the CISA ADP entry also gives 7.5. Cisco, the CNA, maps it to CWE-399 and scores it 8.6 under CVSS 3.0 with a changed scope (NVD, CVE record).

Which switches are affected?

Cisco's advisory cisco-sa-20180328-smi (bug CSCvd40673) covers devices running a vulnerable IOS or IOS XE release "and have the Smart Install client feature enabled". Smart Install is a zero-touch deployment feature for access switches that "incorporates no authentication by design", and the client is enabled by default on releases without the CSCvd36820 fix. show vstack config returning Role: Client with Smart Install enabled means the switch is exposed. Cisco's CSAF file lists 199 affected releases, from IOS 12.2 trains to IOS XE 16.6; a 2018-05-03 update removed the Catalyst 6500 and 6800, which were found not vulnerable.

CISA's ICSA-18-107-04 lists Allen-Bradley Stratix 5400, 5410, 5700, 8000 and ArmorStratix 5700 industrial switches at 15.2(6)E0a and earlier. Rockwell recommends FRN 15.2(6)E1 or later.

How do I fix CVE-2018-0156?

Upgrade to the first fixed release that the Cisco IOS Software Checker returns. Cisco has no workaround for sites that need Smart Install; everyone else can disable it with no vstack, and releases with the CSCvd36820 fix disable it automatically when it is not in use. The ICSA quotes Cisco's note that express setup turns Smart Install off but upgraded switches that were not set up again may still run it, and that sites keeping it on can block inbound TCP 4786 with ACLs. Keep switch management ports off the internet, as in our CISA BOD 23-02 guide, and segment plant switches as in OT/ICS security for small manufacturers.

Is CVE-2018-0156 exploited?

Yes. Cisco updated the advisory on 2022-12-15: in March 2022 PSIRT "became aware of additional attempted exploitation of this vulnerability in the wild." CISA added CVE-2018-0156 to the KEV catalog on 2022-03-03 with the required action "Apply updates per vendor instructions." (due 2022-03-17; known ransomware campaign use: Unknown); it is still listed as of 2026-11-25 in catalog version 2026.11.24. FIRST EPSS gives 0.0936, the 95.47th percentile, in the 2026-11-24 dataset (FIRST EPSS). The Smart Install code execution flaw CVE-2018-0171 uses the same TCP 4786 listener and has its own KEV entry; the IKEv2 leak CVE-2018-0158 hit the same Stratix switches.

How to fix this class of issueNo dedicated SoftWSP guide covers this weakness class; the fix is usually the vendor patch or firmware update referenced above. Our related guide explains how to plan and verify it: NIST SP 800-40 Rev. 4: enterprise patch management planning, explained.

Evidence

  • NVD: Smart Install of Cisco IOS and IOS XE, improper validation of packet data, crafted packet on TCP port 4786, reload; only Smart Install client switches affected, director not affected; NVD Primary CVSS v3.1 7.5 AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H; NVD Primary CVSS v2 7.8; NVD CWE-20, Cisco CWE-399; CPEs ios and ios_xe 15.2(2)E4 and 15.2(2a)JA; bug CSCvd40673; published 2018-03-28; status Analyzed. — NVD
  • Cisco advisory cisco-sa-20180328-smi (v1.7, 2022-12-15): Smart Install client enabled by default without CSCvd36820 fix; no authentication by design; show vstack config; no workaround for customers who need Smart Install, no vstack disables it; 2018-05-03 Catalyst 6500 and 6800 identified as not vulnerable; March 2022 additional attempted exploitation; IOS XR and NX-OS not affected. — Cisco Security Advisory
  • Cisco CSAF cisco-sa-20180328-smi: CVSS 3.0 8.6 (S:C); 199 known affected releases (134 IOS, 65 IOS XE). — Cisco CSAF
  • ICSA-18-107-04: Allen-Bradley Stratix 5400, 5410, 5700, 8000, ArmorStratix 5700 versions 15.2(6)E0a and earlier affected by CVE-2018-0156; Rockwell recommends FRN 15.2(6)E1 or later; Snort rule 41725; Cisco note: Smart Install turned off by express setup, upgraded switches not re-setup may have it enabled, disable with no vstack, or block TCP 4786 with ACLs. — CISA ICS advisory (CSAF)
  • CVE record: state PUBLISHED, CNA Cisco, published 2018-03-28; CISA ADP Vulnrichment CVSS v3.1 7.5 (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). — CVE.org
  • KEV catalog version 2026.11.24: CVE-2018-0156 dateAdded 2022-03-03, required action 'Apply updates per vendor instructions.', due 2022-03-17, knownRansomwareCampaignUse Unknown; checked 2026-11-25. — CISA KEV
  • EPSS 0.0936, percentile 0.9547, dataset 2026-11-24, read 2026-11-25. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. Cisco Security Advisory cisco-sa-20180328-smi
  3. Cisco CSAF cisco-sa-20180328-smi
  4. CISA ICSA-18-107-04: Rockwell Automation Stratix and ArmorStratix switches (CSAF)
  5. CVE.org record CVE-2018-0156 (CNA: Cisco)
  6. CISA KEV
  7. FIRST EPSS

Frequently asked questions

How do I check whether a switch is exposed to CVE-2018-0156?

Run `show vstack config` on the switch. A client role with Smart Install enabled means it listens on TCP 4786 and is exposed if the release is vulnerable. Devices configured as a Smart Install director are not affected (per Cisco's cisco-sa-20180328-smi advisory).

Which firmware fixes CVE-2018-0156?

Cisco lists 199 affected IOS and IOS XE releases and gives first fixed releases through the Cisco IOS Software Checker. For Allen-Bradley Stratix 5400, 5410, 5700, 8000 and ArmorStratix 5700 switches, Rockwell recommends FRN 15.2(6)E1 or later (per Cisco and CISA ICSA-18-107-04).

What if I cannot upgrade right away?

Disable Smart Install with the `no vstack` command if you do not use it. Where it must stay on, block inbound TCP port 4786 with ACLs. Cisco notes there is no workaround for sites that need Smart Install, so upgrading remains the fix (per Cisco and CISA ICSA-18-107-04).

Is CVE-2018-0156 exploited in the wild?

Yes. Cisco PSIRT saw additional attempted exploitation in March 2022, and CISA added it to KEV on 2022-03-03; it is listed as of 2026-11-25 in catalog version 2026.11.24. FIRST EPSS gives 0.0936, the 95.47th percentile, in the 2026-11-24 dataset (per Cisco, CISA KEV and FIRST EPSS).