CVE-2017-6034 is an authentication bypass by capture-replay in Schneider Electric's Modicon Modbus protocol: commands travel in cleartext, so an attacker who records traffic can replay run, stop, upload and download to the controller. NVD scores it 9.8, and Schneider names Modicon M1E, M340, M580, Premium, Quantum, M221 and SCADAPack RTUs as affected.
Vulnerability summary
CVSS base score
9.8
Critical severity
EPSS score (FIRST)
5.6%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2017-6034 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| Schneider Electric Modicon Modbus protocol (Modbus service) | cpe:2.3:o:schneider-electric:modbus_firmware:-:*:*:*:*:*:*:* | all versions (NVD, CISA ICSA-17-101-01) |
| Modicon Momentum M1E 171CBU98090 and 171CBU98091 | — | all versions; no built-in compensating controls, block port 502 at a firewall (Schneider SEVD-2017-065-01, CISA ICSA-17-101-01) |
| Modicon M340, M580, Premium and Quantum | — | M340 before V2.70, M580 before V2.01, Premium before V3.10, Quantum before V3.12 (Schneider SEVD-2017-065-01) |
| Modicon M221 | — | all versions (Schneider SEVD-2017-065-01) |
| SCADAPack 32, 300, 300E/500E and 57x RTUs | — | all versions (Schneider SEVD-2017-065-01) |
What does this mean for affected devices?
NVD describes CVE-2017-6034 as an issue where "sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download." NVD's Primary score is CVSS v3.0 9.8 (critical), vector CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, with CWE-287 as its Primary weakness; CISA's record gives CWE-294, Authentication Bypass by Capture-Replay (NVD).
CISA published ICSA-17-101-01 on 11 April 2017. CISA scores the issue 10.0 with a changed scope (S:C), which is the figure our Modbus protocol security guide quotes from that advisory; NVD's own Primary rating is 9.8. The advisory lists the affected product as the Modicon Modbus protocol, all versions, deployed worldwide across sectors from energy to water.
Schneider Electric's security notification SEVD-2017-065-01 (V3.0, 13 August 2019) names the devices:
- Modicon Momentum M1E 171CBU98090 and 171CBU98091, all versions
- Modicon M340 before V2.70, M580 before V2.01, Premium before V3.10 and Quantum before V3.12
- Modicon M221, all versions
- SCADAPack 32, 300, 300E/500E and 57x RTUs, all versions
Schneider's test is simple: "If you use the Modbus service on one of the affected products versions, your solution is affected." Version 2 of the notice (9 July 2019) added the SCADAPack RTUs, and version 3 corrected the CVE ID from CVE-2017-6028 to CVE-2017-6034. Schneider credits Eran Goldstein of CRITIFENCE, Benjamin Green of Lancaster University and Seok Min Lim of Trustwave.
The remediation is configuration, not a firmware download. M1E owners must block all remote access to port 502, because CISA says those controllers "do not have built-in compensating controls." On M340, M580, Premium and Quantum, Schneider asks for at least one of: the Application Password feature, an input or front-panel key switch (Quantum) that rejects remote run/stop commands, or the Access Control List of pre-authorised IP addresses. M221 and SCADAPack owners should firewall port 502 and disable unused protocols, especially the programming protocol.
The same advisory carries a second finding, CVE-2017-6032, a session weakness open to brute force. Replay works because classic Modbus has no authentication at all, which the Modbus guide explains together with Modbus/TCP Security (TLS on port 802). For the fix pattern as a class, see the authentication bypass fix guide; a comparable Modbus parser flaw in another PLC is CVE-2021-22659 on the Rockwell MicroLogix 1400.
CVE-2017-6034 is not in the CISA KEV catalog as of 2026-11-17 (catalog version 2026.11.13). FIRST EPSS gives it 0.056, the 93rd percentile, in the 2026-11-16 dataset (CISA KEV, FIRST EPSS).
Evidence
- Cleartext Modicon Modbus allows replay of run, stop, upload and download; NVD Primary CVSS v3.0 9.8, vector AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H; Primary CWE-287, CISA CWE-294. — NVD
- ICSA-17-101-01 published 11 April 2017; CISA CVSS v3 10.0 (S:C); M1E controllers lack built-in compensating controls; mitigations: port 502 firewall, Application Password, input or key switch, Access Control List. — CISA ICSA-17-101-01
- Affected: Momentum M1E 171CBU98090/98091 all versions, M340 before V2.70, M580 before V2.01, Premium before V3.10, Quantum before V3.12, M221 all, SCADAPack 32/300/300E/500E/57x all; V2 added SCADAPack; V3 corrected CVE ID from CVE-2017-6028; CVSS 9.8; researcher credits. — Schneider Electric SEVD-2017-065-01 V3.0
- Not in the CISA KEV catalog as of 2026-11-17 (catalog version 2026.11.13). — CISA KEV
- EPSS 0.056 (93rd percentile), dataset 2026-11-16, read 2026-11-17. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which Schneider devices are affected by CVE-2017-6034?
Schneider lists Modicon Momentum M1E 171CBU98090 and 171CBU98091, M340 before V2.70, M580 before V2.01, Premium before V3.10, Quantum before V3.12, M221 and the SCADAPack 32, 300, 300E/500E and 57x RTUs (per Schneider SEVD-2017-065-01).
Is there a firmware fix for CVE-2017-6034?
Schneider's notice gives configuration measures rather than a download: Application Password, an input or key switch that rejects remote run/stop, the Access Control List, and a firewall on port 502. Momentum M1E has no built-in controls, so the firewall is its only measure (per Schneider and CISA ICSA-17-101-01).
Why does CISA say 10.0 when NVD says 9.8?
CISA scored the advisory with a changed scope (S:C), giving 10.0. NVD's own Primary CVSS v3.0 analysis keeps the scope unchanged and gives 9.8 (per CISA ICSA-17-101-01 and NVD).
Is CVE-2017-6034 in the CISA KEV catalog?
No, not as of 2026-11-17 (catalog version 2026.11.13). FIRST EPSS gives it 0.056, the 93rd percentile, in the 2026-11-16 dataset (per CISA KEV and FIRST EPSS).