  • CVE-2017-13082

CVE-2017-13082 is the access point side of KRACK: a Wi-Fi access point with IEEE 802.11r Fast BSS Transition enabled accepts a replayed reassociation request and reinstalls the session key, so an attacker in radio range can replay, decrypt or forge frames. hostapd is affected only with FT on; Rockwell and Siemens industrial access points are named.

Vulnerability summary

CVSS base score

8.1

High severity

EPSS score (FIRST)

4.6%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2017-13082 · Source: NVD

Affected components

ComponentCPEVersion range
hostapd (w1.fi hostap project) with Fast BSS Transition enabledcpe:2.3:a:w1.fi:hostapd:*:*:*:*:*:*:*:*v0.7.2 and newer with FT enabled at runtime, up to 2.6 (w1.fi 2017-1); fixed in 2.7
Rockwell Automation Stratix 5100 wireless access point / workgroup bridge—before 15.3(3) JC1 (CISA ICS advisory ICSA-17-299-02)
Siemens SCALANCE WLC711 and WLC712—before V9.21.19.003; affected by CVE-2017-13082 only with 802.11r activated (Siemens SSA-901333)

What does this mean for affected devices?

CVE-2017-13082 is the KRACK variant that targets access points rather than clients. CERT/CC's VU#228519 describes it as "accepting a retransmitted Fast BSS Transition Reassociation Request and reinstalling the pairwise key while processing it". NVD scores it 8.1 under CVSS v3.0, vector CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N, with CWE-330 as primary weakness and CWE-323 (reusing a nonce, key pair in encryption) as secondary (NVD). Unlike the client-side CVE-2017-13077, the attack complexity is low, which is why the score is higher.

Only when Fast BSS Transition is on. The w1.fi 2017-1 advisory says the AP-side issue applies "in the case where hostapd is used to operate an RSN/WPA2 network with FT (Fast BSS Transition from IEEE 802.11r) enabled", and lists "hostapd v0.7.2 and newer with FT enabled" as vulnerable, adding that "FT needs to be enabled in the runtime configuration". On the transmit side the AP resets its packet number to zero, which with CCMP means nonce reuse. The upstream fix is the commit "hostapd: Avoid key reinstallation in FT handshake", released in hostapd 2.7, and the advisory names disabling FT as a temporary workaround.

CISA's ICS advisory ICSA-17-299-02 (initial release 2017-10-26, Update A on 2018-11-01, CSAF record) names the Rockwell Automation Stratix 5100 wireless access point and workgroup bridge before firmware 15.3(3) JC1 and scores CVE-2017-13082 at 6.9 (AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:N). Rockwell later found that 802.11r "is not fully supported" on the Stratix 5100, so units in access point mode are not affected and patching them as access points is not required; it still advises patching the wireless clients. Siemens SSA-901333 says SCALANCE WLC711 and WLC712 controllers "are only affected by CVE-2017-13082 if they have 802.11r functionality activated", which is off by default, and fixes them in V9.21.19.003. Siemens scores this CVE at 6.8 for its products.

The CVE is not in the CISA KEV catalog as of 2026-11-16 (catalog version 2026.11.13), and FIRST EPSS gives it 0.04575, the 91.77th percentile, in the 2026-11-15 dataset (CISA KEV, FIRST EPSS). It is high on access points with FT enabled and does not apply without FT, so the runtime configuration decides the result, not the version alone.

Ship hostapd 2.7 or later, or backport the 2017-1 commit, and check whether any FT entry appears in wpa_key_mgmt in the shipped configuration. If you cannot update, remove FT until you can. For Rockwell and Siemens devices, follow ICSA-17-299-02 and SSA-901333. Our hostapd and wpa_supplicant vulnerabilities guide explains how to read the FT setting from a firmware image, and the KEV and EPSS prioritisation guide explains why a 91st-percentile EPSS score still needs that configuration check.

How to fix this class of issueNo dedicated SoftWSP guide covers this weakness class; the fix is usually the vendor patch or firmware update referenced above. Our related guide explains how to plan and verify it: NIST SP 800-40 Rev. 4: enterprise patch management planning, explained.

Evidence

  • CVE-2017-13082: accepting a retransmitted FT Reassociation Request and reinstalling the pairwise key (CERT/CC VU#228519). — CERT/CC VU#228519
  • NVD CVSS v3.0 8.1 (CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N), CWE-330 primary, CWE-323 secondary, published 2017-10-17. — NVD
  • hostapd v0.7.2 and newer with FT enabled at runtime are vulnerable; fix commit 'hostapd: Avoid key reinstallation in FT handshake'; disable FT as workaround; update to v2.7. — w1.fi security advisory 2017-1
  • ICSA-17-299-02 (2017-10-26, Update A 2018-11-01): Stratix 5100 before 15.3(3) JC1, CVSS 6.9; AP mode not affected because 802.11r is not fully supported. — CISA ICS advisory ICSA-17-299-02 (CSAF)
  • SCALANCE WLC711/WLC712 affected by CVE-2017-13082 only with 802.11r activated (off by default); fixed in V9.21.19.003; Siemens CVSS 6.8. — Siemens ProductCERT SSA-901333
  • Not in the CISA KEV catalog as of 2026-11-16 (catalog version 2026.11.13). — CISA KEV
  • EPSS 0.04575 (91.77th percentile), dataset 2026-11-15, read 2026-11-16. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CERT/CC VU#228519: WPA handshake traffic can be manipulated to induce nonce and session key reuse
  3. w1.fi security advisory 2017-1: WPA packet number reuse with replayed messages and key reinstallation
  4. CISA ICS advisory ICSA-17-299-02: Rockwell Automation Stratix 5100 (CSAF)
  5. Siemens ProductCERT SSA-901333: KRACK Attacks Vulnerabilities in Industrial Products
  6. CISA KEV
  7. FIRST EPSS

Frequently asked questions

Is my access point affected by CVE-2017-13082 if Fast BSS Transition is off?

No. The w1.fi 2017-1 advisory says the hostapd issue applies only to networks with FT (IEEE 802.11r) enabled and that FT must be enabled in the runtime configuration. Siemens likewise says SCALANCE WLC711 and WLC712 are affected only with 802.11r activated, which is off by default.

Why does NVD score CVE-2017-13082 higher than the client-side KRACK CVEs?

NVD rates its attack complexity as low (AC:L), giving CVSS v3.0 8.1, while CVE-2017-13077 has high complexity (AC:H) and scores 6.8 (per NVD).

Is the Rockwell Stratix 5100 affected?

CISA ICSA-17-299-02 lists Stratix 5100 firmware before 15.3(3) JC1. Rockwell later determined that access point mode is not affected because 802.11r is not fully supported on the device, and recommends patching the wireless clients that connect to it (per the CISA CSAF record).

Is CVE-2017-13082 in the CISA KEV catalog?

No, not as of 2026-11-16 (catalog version 2026.11.13). FIRST EPSS gives it 0.04575, the 91.77th percentile, in the 2026-11-15 dataset (per CISA KEV and FIRST EPSS).