CVE-2017-13077 is the core KRACK flaw: a Wi-Fi client can be tricked into reinstalling the WPA2 pairwise key during the four-way handshake, which resets its packet counters so an attacker in radio range can replay, decrypt or forge frames. It hits wpa_supplicant-based IoT clients and industrial Wi-Fi gear such as Siemens SCALANCE W-700.
Vulnerability summary
CVSS base score
6.8
Medium severity
EPSS score (FIRST)
2.4%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2017-13077 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| wpa_supplicant (w1.fi hostap project) | cpe:2.3:a:w1.fi:wpa_supplicant:*:*:*:*:*:*:*:* | all versions up to 2.6 per the w1.fi 2017-1 advisory; patches for 2.6 published 2017-10-16, fixed in 2.7 |
| Siemens SCALANCE W-700 (IEEE 802.11n) | — | all versions before V6.2.1 (Siemens SSA-901333) |
| Siemens RUGGEDCOM RX1400 with WLAN interface | — | all versions before V2.11.2; not vulnerable in access point mode (Siemens SSA-901333) |
| Siemens SINAMICS V20 Smart Access Module | — | all versions before V01.03.01 (Siemens SSA-901333) |
What does this mean for affected devices?
CVE-2017-13077 is the first of the ten Key Reinstallation Attack (KRACK) identifiers that CERT/CC published on 2017-10-16 in VU#228519: "reinstallation of the pairwise key in the Four-way handshake". An attacker who can sit between a client and its access point replays handshake message 3, the client installs the same key again, and its nonce and replay counters go back to their start values. NVD scores it 6.8 under CVSS v3.0, vector CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N, weakness CWE-330 (NVD). The attacker must be in radio range, and no credentials are needed.
The w1.fi 2017-1 advisory says all wpa_supplicant versions were affected by the station-side issues, and the impact depends on the version: "v2.3 and older can also reinstall the pairwise key", while "v2.4 and v2.5 end up configuring an all-zero TK", which could let an attacker "decrypt all following frames from the station and to inject arbitrary frames to the station". Upstream published patches against 2.6 on the day of disclosure and told users to update to v2.7. On the access point side, hostapd is exposed to the related FT case, CVE-2017-13082, only when Fast BSS Transition is enabled.
Any embedded Linux client that joins WPA2 networks with an unpatched wpa_supplicant: sensors, gateways, HMIs, set-top boxes. Industrial vendors confirmed it in their own products. Siemens ProductCERT SSA-901333 (first published 2017-11-09, last updated 2019-04-09 at V1.6) lists SCALANCE W-700 (IEEE 802.11n) before V6.2.1, RUGGEDCOM RX1400 with WLAN before V2.11.2, SCALANCE W1750D, SCALANCE WLC711 and WLC712, and the SINAMICS V20 Smart Access Module before V01.03.01 as fixed in later firmware. For RUGGEDCOM RS9xxW, SCALANCE W-700 (IEEE 802.11a/b/g), SIMATIC ET200 PRO IM154-6 PN IWLAN, SIMATIC IWLAN-PB/LINK and SIMATIC Mobile Panel 277(F) IWLAN it gives workarounds only. Siemens scores CVE-2017-13077 at 4.2 for its products and notes that RX1400 and RS9xxW are not vulnerable in access point mode, which fits KRACK being a client-side attack.
The CVE is not in the CISA KEV catalog as of 2026-11-16 (catalog version 2026.11.13), and FIRST EPSS gives it 0.02388, the 84.22nd percentile, in the 2026-11-15 dataset (CISA KEV, FIRST EPSS). Treat it as high on IoT and industrial clients running wpa_supplicant before 2.7, and critical on 2.4 and 2.5 because of the all-zero key.
Ship wpa_supplicant 2.7 or later, or backport the 2017-1 patches, and check the version string in the firmware image rather than the vendor's release notes. For Siemens devices, install the versions named in SSA-901333; where Siemens offers only workarounds, use WPA2-CCMP (AES), which Siemens says limits the attack to decryption and replay of parts of the traffic, and do not rely on WPA2 alone. Our hostapd and wpa_supplicant vulnerabilities guide shows how to read the version and build options from an image, and our weak cryptography fix guide covers nonce and key handling in firmware.
Evidence
- CVE-2017-13077 is reinstallation of the pairwise key in the four-way handshake; CERT/CC VU#228519 released 2017-10-16. — CERT/CC VU#228519
- NVD CVSS v3.0 6.8 (CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N), CWE-330, published 2017-10-17. — NVD
- All wpa_supplicant versions affected; v2.3 and older reinstall the pairwise key; v2.4 and v2.5 configure an all-zero TK; update to v2.7. — w1.fi security advisory 2017-1
- SSA-901333 V1.6 (2019-04-09) lists SCALANCE W-700 (802.11n) < V6.2.1, RUGGEDCOM RX1400 WLAN < V2.11.2, SINAMICS V20 Smart Access Module < V01.03.01 and other industrial products; Siemens CVSS 4.2 for CVE-2017-13077. — Siemens ProductCERT SSA-901333
- Not in the CISA KEV catalog as of 2026-11-16 (catalog version 2026.11.13). — CISA KEV
- EPSS 0.02388 (84.22nd percentile), dataset 2026-11-15, read 2026-11-16. — FIRST EPSS

Related advisories
Sources
- NVD
- CERT/CC VU#228519: WPA handshake traffic can be manipulated to induce nonce and session key reuse
- w1.fi security advisory 2017-1: WPA packet number reuse with replayed messages and key reinstallation
- Siemens ProductCERT SSA-901333: KRACK Attacks Vulnerabilities in Industrial Products
- CISA KEV
- FIRST EPSS
Frequently asked questions
Is CVE-2017-13077 a client or an access point problem?
A client problem. It is the reinstallation of the pairwise key in the four-way handshake on the station side (per CERT/CC VU#228519). The w1.fi advisory says all wpa_supplicant versions were affected, while the access point case in hostapd is the separate CVE-2017-13082, which needs Fast BSS Transition enabled.
Why are wpa_supplicant 2.4 and 2.5 worse than other versions?
Because they install an all-zero temporal key after the replay. The w1.fi 2017-1 advisory says this could allow an attacker to decrypt all following frames from the station and inject arbitrary frames to it, while v2.3 and older reinstall the real pairwise key.
Which Siemens industrial products does CVE-2017-13077 affect?
SSA-901333 lists SCALANCE W-700, W1750D, WLC711 and WLC712, RUGGEDCOM RX1400 with WLAN and RS9xxW, SIMATIC ET200 PRO IM154-6 PN IWLAN, IWLAN-PB/LINK, Mobile Panel 277(F) IWLAN and the SINAMICS V20 Smart Access Module. Some have fixed firmware, such as SCALANCE W-700 (802.11n) V6.2.1; others have workarounds only (per Siemens ProductCERT).
Is CVE-2017-13077 exploited in the wild?
It is not in the CISA KEV catalog as of 2026-11-16 (catalog version 2026.11.13). FIRST EPSS gives it 0.02388, the 84.22nd percentile, in the 2026-11-15 dataset (per CISA KEV and FIRST EPSS).