Security Advisory

CVE-2026-85115: Siemens S7 Webserver API Client Password Leak (pending)

Last updated:
  • CVE-2026-85115

CVE-2026-85115 is an information-exposure flaw in the .NET Client Library for Siemens' SIMATIC S7 Webserver API that leaks a PLC's plaintext restore password inside HTTP error exception messages, letting anyone who can read application logs or diagnostic output recover the password and potentially use it against the PLC; NVD has not, as of 2026-10-26, published its own CVSS score.

Vulnerability summary

CVSS base score

N/A

No NVD score published as of

EPSS score (FIRST)

0.1%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2026-85115 · Source: NVD

Affected components

ComponentCPEVersion range
.NET Client Library for SIMATIC S7 Webserver API—All versions before V3.3.62 (fixed in V3.3.62)

What does this mean for affected devices?

CVE-2026-85115 (CWE-209, information exposure through an error message) affects the .NET Client Library for Siemens' SIMATIC S7 Webserver API, versions before V3.3.62. NVD's description states that "affected applications do not properly redact PLC restore passwords from HTTP error exception messages," which "could allow an attacker with access to logs or other diagnostic output to obtain the plaintext restore password and potentially perform unauthorized operations on the PLC" (NVD).

NVD tracks the CVE with status "Deferred" as of 2026-10-26. The only severity data on record is Siemens' own ProductCERT submission — CVSS v3.1 5.5 (medium), vector CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N, and CVSS v4.0 6.8 (medium) — with no NVD-published independent score, so this page does not show a headline severity score rather than presenting the vendor figure as NVD-confirmed (NVD).

Siemens' product security advisory, republished by CISA as ICS advisory ICSA-26-295-10 on 2026-10-22 (original Siemens publication 2026-10-13), bundles CVE-2026-85115 with a related path-traversal flaw in the same client library (CVE-2026-85114) and recommends updating the .NET Client Library for SIMATIC S7 Webserver API to V3.3.62 or later to fix this issue (V3.3.61 or later fixes the companion CVE) (CISA ICS Advisory ICSA-26-295-10).

This CVE is not listed in the CISA Known Exploited Vulnerabilities catalog as of 2026-10-26, and FIRST scores the probability of exploitation at 0.0011 (1.228th percentile) (CISA KEV, FIRST EPSS).

NVD has not finished its own severity analysis. In the meantime, developers using the .NET Client Library for SIMATIC S7 Webserver API should update to V3.3.62 or later, restrict access to application logs and diagnostic output, and rotate any PLC restore password that may already have been logged in plaintext.

How to fix this class of issueNo dedicated SoftWSP guide covers this weakness class; the fix is usually the vendor patch or firmware update referenced above. Our related guide explains how to plan and verify it: NIST SP 800-40 Rev. 4: enterprise patch management planning, explained.

Evidence

  • The .NET Client Library for SIMATIC S7 Webserver API (before V3.3.62) fails to redact PLC restore passwords from HTTP error exception messages, exposing the plaintext password to anyone with log access (CWE-209). — NVD
  • NVD status is "Deferred" with a Siemens-ProductCERT-submitted CVSS v3.1 5.5 (medium) and CVSS v4.0 6.8 (medium); no NVD-published independent score as of 2026-10-26. — NVD
  • Bundled with the related path-traversal CVE-2026-85114 in the same client library; fix is .NET Client Library for SIMATIC S7 Webserver API V3.3.62 or later. — CISA ICS Advisory ICSA-26-295-10
  • Not present in the CISA KEV catalog as of 2026-10-26. — CISA KEV
  • EPSS score is 0.0011 (1.228th percentile) as of 2026-10-26. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICS Advisory ICSA-26-295-10
  3. CISA KEV
  4. FIRST EPSS

Frequently asked questions

What is CVE-2026-85115?

CVE-2026-85115 is an information-exposure flaw in the .NET Client Library for Siemens' SIMATIC S7 Webserver API that leaks a PLC's plaintext restore password inside HTTP error exception messages, letting anyone who can read application logs or diagnostic output recover the password and potentially use it against the PLC; NVD has not, as of 2026-10-26, published its own CVSS score.

How severe is CVE-2026-85115?

CVE-2026-85115 has no NVD CVSS score published as of 2026-11-10, so this page gives it no severity rating rather than assuming low or high risk.

Is CVE-2026-85115 being actively exploited?

CVE-2026-85115 is not listed in the CISA Known Exploited Vulnerabilities (KEV) catalog. FIRST's EPSS model puts its probability of exploitation at 0.11%.

What is affected by CVE-2026-85115?

CVE-2026-85115 affects .NET Client Library for SIMATIC S7 Webserver API.

Where does this CVE-2026-85115 information come from?

This advisory is based on NVD, CISA ICS Advisory ICSA-26-295-10, CISA KEV, and FIRST EPSS, cited in full in the Sources section above.