Security Advisory

CVE-2026-83549: SonicWall SMA1000 Post-Auth OS Command Injection (KEV)

Last updated:
  • CVE-2026-83549

CVE-2026-83549 is a post-authentication OS command injection in the Appliance Management Console (AMC) of SonicWall's SMA1000 remote-access appliances that lets an already-authenticated administrator execute arbitrary OS commands, and CISA added it to the KEV catalog the same day as the related pre-auth SSRF CVE-2026-83548 from the same SonicWall bulletin, with a forensic-triage requirement rather than patching alone.

Vulnerability summary

CVSS base score

7.8

High severity

EPSS score (FIRST)

9.9%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

Yes

Listed as known exploited

Published

Vulnerability ID: CVE-2026-83549 · Source: NVD (CISA-ADP Secondary score only, not NVD Primary)

Affected components

ComponentCPEVersion range
SonicWall SMA1000 Appliances (SMA8200v, SMA6210, SMA7210)cpe:2.3:a:sonicwall:sma8200v:*:*:*:*:*:*:*:*SMA8200v, SMA6210 firmware and SMA7210 firmware: before 12.4.3-03526 (fixed in 12.4.3-03526); 12.5.0 and later before 12.5.0-02952 (fixed in 12.5.0-02952)

What does this mean for affected devices?

CVE-2026-83549 is an Improper Neutralization of Special Elements used in an OS Command (CWE-78) vulnerability in SonicWall SMA1000 appliances. NVD's Analyzed record describes it as a "Post-authentication Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability" in "the SMA1000 Appliance Management Console (AMC) which in specific conditions could potentially enable a remote authenticated attacker as administrator to execute arbitrary OS commands, resulting in remote code execution" (NVD).

NVD has not published its own independent Primary CVSS score for this record; the only metric on file is a CISA-ADP Secondary rating of CVSS v3.1 7.8 (high), vector CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H — local attack vector, low privileges required, no user interaction, high impact to confidentiality, integrity and availability. So the 7.8 shown here is the CISA-ADP Secondary score, not an NVD-confirmed Primary score (NVD).

SonicWall's own PSIRT advisory page for this CVE (SNWLID-2026-0016) — the same bulletin ID cited for the related CVE-2026-83548 — is a client-rendered JavaScript application with no advisory text in the static HTML; the affected-product list and fixed-version numbers below come from NVD's structured configuration data instead, which names SMA8200v (software) and the SMA6210/SMA7210 firmware as vulnerable before build 12.4.3-03526, and in the 12.5.0 branch before build 12.5.0-02952 — identical to the affected range published for CVE-2026-83548 (NVD).

CISA added CVE-2026-83549 to the Known Exploited Vulnerabilities (KEV) catalog on 2026-09-02, with a required-action due date of 2026-09-05 — a three-day window — and marks this CVE as requiring CISA's forensic-triage guidance under BOD 26-04, the same treatment given to CVE-2026-83548 from the same bulletin. Known ransomware campaign use is recorded as "Unknown." (CISA KEV).

As of 2026-10-28, FIRST scores the probability of exploitation at 0.09889 (95.557th percentile) (FIRST EPSS).

Because SonicWall's PSIRT page does not expose advisory text directly, any organization running SMA1000 appliances should confirm current firmware against SonicWall's MySonicWall portal directly and upgrade to the fixed builds immediately given the short KEV remediation window, CISA's forensic-triage flag, and the fact this is one of two actively exploited CVEs from the same bulletin.

How to fix this class of issueThis advisory's weakness class is Command injection. Our practical guide covers how to detect, fix, verify and disclose it: How to fix command injection in embedded firmware.

Evidence

  • Post-authentication OS command injection in the SonicWall SMA1000 Appliance Management Console (AMC), letting a remote authenticated administrator execute arbitrary OS commands resulting in RCE. — NVD
  • CVSS v3.1 base score is 7.8 (high), vector CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H — a CISA-ADP Secondary rating; NVD has not published its own Primary score. — NVD
  • Affected: SMA8200v software and SMA6210/SMA7210 firmware before build 12.4.3-03526, and 12.5.0 branch before build 12.5.0-02952 (fixed at those builds); SonicWall's own PSIRT advisory page (SNWLID-2026-0016, shared with CVE-2026-83548) is a client-rendered JavaScript app with no readable advisory text. — NVD
  • Added to the CISA Known Exploited Vulnerabilities catalog on 2026-09-02, required-action due date 2026-09-05, flagged for CISA's forensic-triage requirement under BOD 26-04, ransomware use Unknown. — CISA KEV
  • EPSS score is 0.09889 (95.557th percentile) as of 2026-10-28. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA KEV
  3. FIRST EPSS

Frequently asked questions

Does an attacker need to already be logged in to exploit CVE-2026-83549?

Yes. Unlike the related pre-auth SSRF CVE-2026-83548 from the same bulletin, this flaw requires the attacker to already be a remote authenticated administrator on the SMA1000 Appliance Management Console (AMC) before they can inject OS commands (per NVD).

Is the 7.8 CVSS score for this CVE an NVD-confirmed Primary score?

No. NVD has not published its own independent Primary score; the only metric on file is a CISA-ADP Secondary rating of CVSS v3.1 7.8 (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) (per NVD).

Are CVE-2026-83549 and CVE-2026-83548 related?

Yes — both were disclosed in the same SonicWall bulletin (SNWLID-2026-0016), affect the identical SMA8200v/SMA6210/SMA7210 build ranges, and were both added to the CISA KEV catalog on the same day, 2026-09-02, with the same three-day remediation window (per NVD; per CISA KEV).

Which SMA1000 builds fix the OS command injection?

SMA8200v software and SMA6210/SMA7210 firmware before build 12.4.3-03526, and the 12.5.0 branch before build 12.5.0-02952, are affected; those exact builds contain the fix (per NVD).

Why isn't SonicWall's own advisory text cited directly in this entry?

SonicWall's PSIRT page for SNWLID-2026-0016 is a client-rendered JavaScript application with no advisory text in the static HTML, so the affected-version data here is instead drawn from NVD's structured configuration data.