CVE-2026-33389 is a missing host/certificate validation flaw in Nozomi Networks' Smart Polling feature that lets a man-in-the-middle attacker impersonate a polled OT device, intercept credentials, and replay them for unauthorized access; it also affects the Nozomi Guardian/CMC software Siemens OEMs on its RUGGEDCOM APE1808 edge appliance, and NVD has not, as of 2026-10-26, completed its own CVSS scoring.
Vulnerability summary
CVSS base score
N/A
No NVD score published as of
EPSS score (FIRST)
0.2%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2026-33389 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| Nozomi Networks Guardian / CMC / Arc (Smart Polling feature), including the Nozomi Guardian/CMC stack bundled on Siemens RUGGEDCOM APE1808 | — | Nozomi Guardian before 26.3.0; Nozomi CMC before 26.3.0; Nozomi Arc before 2.7.0; Siemens RUGGEDCOM APE1808 running an affected Nozomi Guardian/CMC version — Siemens has published no fixed version for the APE1808 OEM build and directs customers to Siemens customer support. |
What does this mean for affected devices?
CVE-2026-33389 (CWE-671, improper restriction of rendered content used here for a missing host-identity check) affects Nozomi Networks' Smart Polling, a feature of Nozomi Guardian and Nozomi CMC that actively queries OT/ICS devices for asset and vulnerability data. NVD's description states Smart Polling "allowed establishing encrypted connections to target devices without properly validating the remote host's identity," letting "an on-path attacker who can intercept the communication between the product and a target device" impersonate that device, "intercept sensitive information (e.g., credentials used for polling)" and potentially replay it "to gain unauthorized access to other systems or disrupt the operations of monitored devices" (NVD).
NVD tracks the CVE with status "Awaiting Analysis" as of 2026-10-26: it records a CVSS v3.1 submission of 7.5 (high), vector CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:L, attributed to Nozomi Networks as the submitting source, but has not published its own independent score, so this page does not show a headline severity score rather than presenting Nozomi's figure as NVD-confirmed (NVD).
Nozomi Networks' own advisory NN-2026:20-01 confirms the flaw in Smart Polling and lists fixed versions: Nozomi Guardian 26.3.0, Nozomi CMC 26.3.0, and Nozomi Arc 2.7.0 (Nozomi Networks Security Advisory NN-2026:20-01).
Siemens republished the same CVE in Security Advisory SSA-911336 on 2026-10-13 because Nozomi Guardian/CMC ships as the embedded OEM monitoring stack on the Siemens RUGGEDCOM APE1808 industrial edge appliance; Siemens bundles it alongside four related Smart Polling and Credentials Manager issues (CVE-2026-33387, CVE-2026-33388, CVE-2026-33391, CVE-2026-33920) affecting the same APE1808 product, and tells customers to contact Siemens customer support for a patch rather than publishing a fixed APE1808 firmware version directly in the advisory (Siemens Security Advisory SSA-911336).
This CVE is not listed in the CISA Known Exploited Vulnerabilities catalog as of 2026-10-26, and FIRST scores the probability of exploitation at 0.00167 (5.929th percentile) as of 2026-10-25 (CISA KEV, FIRST EPSS).
NVD has not finished its own severity analysis. In the meantime, operators running Nozomi Guardian/CMC/Arc directly, or a Siemens RUGGEDCOM APE1808 with the bundled Nozomi stack, should update to the fixed Nozomi versions where applicable or contact Siemens support for the APE1808 OEM build, and restrict network access to Smart Polling traffic to trusted segments.
Evidence
- Smart Polling establishes encrypted connections without validating the remote host's identity, letting an on-path attacker impersonate a polled device, intercept credentials, and replay them for unauthorized access or disruption (CWE-671). — NVD
- NVD status is "Awaiting Analysis" with a Nozomi-submitted CVSS v3.1 score of 7.5 (high), vector CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:L; no NVD-published score as of 2026-10-26. — NVD
- Fixed in Nozomi Guardian 26.3.0, Nozomi CMC 26.3.0, and Nozomi Arc 2.7.0. — Nozomi Networks Security Advisory NN-2026:20-01
- Also affects the Nozomi Guardian/CMC stack bundled on Siemens RUGGEDCOM APE1808; Siemens republished the issue on 2026-10-13 alongside four related CVEs and directs affected customers to Siemens customer support for a patch. — Siemens Security Advisory SSA-911336
- Not present in the CISA KEV catalog as of 2026-10-26; EPSS score is 0.00167 (5.929th percentile) as of 2026-10-25. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
What is CVE-2026-33389?
CVE-2026-33389 is a missing host/certificate validation flaw in Nozomi Networks' Smart Polling feature that lets a man-in-the-middle attacker impersonate a polled OT device, intercept credentials, and replay them for unauthorized access; it also affects the Nozomi Guardian/CMC software Siemens OEMs on its RUGGEDCOM APE1808 edge appliance, and NVD has not, as of 2026-10-26, completed its own CVSS scoring.
How severe is CVE-2026-33389?
CVE-2026-33389 has no NVD CVSS score published as of 2026-11-10, so this page gives it no severity rating rather than assuming low or high risk.
Is CVE-2026-33389 being actively exploited?
CVE-2026-33389 is not listed in the CISA Known Exploited Vulnerabilities (KEV) catalog. FIRST's EPSS model puts its probability of exploitation at 0.17%.
What is affected by CVE-2026-33389?
CVE-2026-33389 affects Nozomi Networks Guardian / CMC / Arc (Smart Polling feature), including the Nozomi Guardian/CMC stack bundled on Siemens RUGGEDCOM APE1808.
Where does this CVE-2026-33389 information come from?
This advisory is based on NVD, Nozomi Networks Security Advisory NN-2026:20-01, Siemens Security Advisory SSA-911336, CISA KEV, and FIRST EPSS, cited in full in the Sources section above.