Security Advisory

CVE-2025-7768: Tigo Energy Cloud Connect Advanced Hard-Coded Credentials Full Device Takeover

Last updated:
  • CVE-2025-7768

CVE-2025-7768 is a hard-coded-credentials flaw (CWE-798) in Tigo Energy's Cloud Connect Advanced (CCA), the on-site gateway appliance that bridges a rooftop solar array's Tigo TS4 module-level power electronics to Tigo's cloud monitoring platform: because the device ships with hard-coded credentials, an unauthorized user can gain administrative access, escalate privileges, and take full control of the device, and NVD has not, as of 2026-11-08, published its own Primary CVSS score — the Secondary rating shown on this page is CISA's.

Vulnerability summary

CVSS base score

N/A

No NVD score published as of

EPSS score (FIRST)

0.6%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2025-7768 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
Tigo Energy Cloud Connect Advanced (CCA), the on-site data-logger/communications gateway that connects Tigo TS4 module-level power electronics in residential and commercial solar PV installations to Tigo's cloud monitoring platform—Cloud Connect Advanced versions 4.0.1 and prior, per CISA's advisory

What does this mean for affected devices?

CVE-2025-7768 (CWE-798, use of hard-coded credentials) affects Tigo Energy's Cloud Connect Advanced. NVD's description states: "Tigo Energy's Cloud Connect Advanced (CCA) device contains hard-coded credentials that allow unauthorized users to gain administrative access. This vulnerability enables attackers to escalate privileges and take full control of the device, potentially modifying system settings, disrupting solar energy production, and interfering with safety mechanisms" (NVD).

The CCA is a physical data-logger and communications gateway: it sits near a building's electrical service panel, talks to Tigo Access Points mounted on the solar array, collects module-level voltage, current, power and temperature telemetry from up to 900 TS4 units, and relays that data to Tigo's Energy Intelligence cloud platform over Ethernet, Wi-Fi or cellular — the same class of grid-facing monitoring-gateway device as the inverters and meters it instruments.

NVD tracks CVE-2025-7768 with status "Deferred": it records only a CISA ICS-CERT-submitted score (source [email protected]) — CVSS v4.0 9.3 (critical), vector CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N — typed Secondary, not NVD's own Primary rating, so this page does not present that figure as NVD-confirmed (NVD).

CISA's advisory ICSA-25-217-02 (published 2025-08-05, updated 2025-08-19) separately calculated a CVSS v3.1 base score of 9.8 (vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H), lists Tigo Energy as the vendor with the Energy sector affected worldwide, and credits Anthony Rose and Jacob Krasnov of BC Security along with Peter Kariuki of Ovanova for reporting this and two companion flaws disclosed in the same advisory: CVE-2025-7769, a command-injection vulnerability in the CCA's /cgi-bin/mobile_api DEVICE_PING endpoint, and CVE-2025-7770, predictable, timestamp-based session-ID generation that lets an attacker forge valid sessions (CISA ICS Advisory ICSA-25-217-02).

Because the flaw requires no credentials, no user interaction and is reachable over the network, CISA's recommended mitigations for affected sites are the standard ICS baseline: isolate the CCA from direct internet access and business networks, deploy it behind a firewall, use a VPN for any required remote access, and monitor for suspected malicious activity (CISA ICS Advisory ICSA-25-217-02).

This CVE is not listed in the CISA Known Exploited Vulnerabilities catalog as of catalog version 2026.11.06, and FIRST scores the probability of exploitation at 0.0063 (50.5th percentile) as of 2026-11-07 — a critical-severity flaw with confirmed CISA scoring but no reported in-the-wild exploitation (CISA KEV, FIRST EPSS).

NVD has not finished its own severity analysis. In the meantime, any Cloud Connect Advanced unit at version 4.0.1 or earlier should be treated as exposed to full administrative takeover by any network-reachable attacker who knows or guesses its hard-coded credentials, and isolated from untrusted networks until a credential-rotation fix from Tigo Energy is applied.

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is Hard-coded credentials. Our practical guide covers how to detect, fix, verify and disclose it: How to fix hard-coded credentials in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • Tigo Energy's Cloud Connect Advanced (CCA) contains hard-coded credentials allowing unauthorized administrative access, privilege escalation, and full device control, potentially modifying system settings, disrupting solar energy production, and interfering with safety mechanisms. — NVD
  • NVD status 'Deferred'; only a CISA ICS-CERT-submitted Secondary CVSS v4.0 base score of 9.3 is recorded, vector CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N. — NVD
  • CISA calculated CVSS v3.1 9.8 (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H); affects CCA versions 4.0.1 and prior in the Energy sector worldwide; reported by Anthony Rose and Jacob Krasnov (BC Security) and Peter Kariuki (Ovanova); companion flaws CVE-2025-7769 (command injection via /cgi-bin/mobile_api DEVICE_PING) and CVE-2025-7770 (predictable session IDs) disclosed in the same advisory. — CISA ICS Advisory ICSA-25-217-02
  • Not present in the CISA KEV catalog as of catalog version 2026.11.06; EPSS score is 0.0063 (50.5th percentile) as of 2026-11-07. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICS Advisory ICSA-25-217-02
  3. CISA KEV
  4. FIRST EPSS

Frequently asked questions

What is CVE-2025-7768?

CVE-2025-7768 is a hard-coded-credentials flaw (CWE-798) in Tigo Energy's Cloud Connect Advanced (CCA), the on-site gateway appliance that bridges a rooftop solar array's Tigo TS4 module-level power electronics to Tigo's cloud monitoring platform: because the device ships with hard-coded credentials, an unauthorized user can gain administrative access, escalate privileges, and take full control of the device, and NVD has not, as of 2026-11-08, published its own Primary CVSS score — the Secondary rating shown on this page is CISA's.

How severe is CVE-2025-7768?

CVE-2025-7768 has no NVD CVSS score published as of 2026-11-10, so this page gives it no severity rating rather than assuming low or high risk.

Is CVE-2025-7768 being actively exploited?

CVE-2025-7768 is not listed in the CISA Known Exploited Vulnerabilities (KEV) catalog. FIRST's EPSS model puts its probability of exploitation at 0.63%.

What is affected by CVE-2025-7768?

CVE-2025-7768 affects Tigo Energy Cloud Connect Advanced (CCA), the on-site data-logger/communications gateway that connects Tigo TS4 module-level power electronics in residential and commercial solar PV installations to Tigo's cloud monitoring platform.

Where does this CVE-2025-7768 information come from?

This advisory is based on NVD, CISA ICS Advisory ICSA-25-217-02, CISA KEV, and FIRST EPSS, cited in full in the Sources section above.