Security Advisory

CVE-2025-6625: Schneider Electric Modicon M340 Denial of Service via Crafted FTP Command

Last updated:
  • CVE-2025-6625

CVE-2025-6625 is a denial-of-service vulnerability (CWE-20, improper input validation) in Schneider Electric's Modicon M340 programmable logic controller and its companion X80 Ethernet/Modbus communication modules: sending a specially crafted FTP command to the device's FTP service can crash it, and because NVD's own analysis of this CVE is still deferred, the CVSS scores shown in sourcing below come from Schneider's own PSIRT submission rather than an NVD-confirmed rating.

Vulnerability summary

CVSS base score

N/A

No NVD score published as of

EPSS score (FIRST)

0.5%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2025-6625 · Source: NVD

Affected components

ComponentCPEVersion range
Schneider Electric Modicon M340 Controller and companion X80 Ethernet/Modbus communication modules (BMXNOE0100, BMXNOE0110, BMXNOR0200H Ethernet/Serial RTU module, M580 Global Data module)—Modicon M340 Controller firmware before SV3.70; BMXNOE0100 (Modbus/TCP Ethernet M340 module) before 3.60; BMXNOE0110 (Modbus/TCP Ethernet M340 FactoryCast module) before 6.80; BMXNOR0200H (Ethernet/Serial RTU module) before SV1.7_IR27; Modicon M580 Global Data module and Modicon M340 X80 Ethernet communication modules, all versions (no fixed version listed for these two as of the advisory)

What does this mean for affected devices?

CVE-2025-6625 (CWE-20, improper input validation) affects Schneider Electric's Modicon M340 controller and several companion communication modules. NVD's description states: "CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device" (NVD).

The Modicon M340 is a physical, rack-mounted mid-range PLC widely used in process and discrete manufacturing. The affected companion modules named in the advisory are the BMXNOE0100 and BMXNOE0110 Modbus/TCP Ethernet communication modules, the BMXNOR0200H Ethernet/Serial RTU module, the M580 Global Data module, and the Modicon M340 X80 Ethernet communication modules (CISA ICS Advisory ICSA-26-260-04).

NVD tracks CVE-2025-6625 with status "Deferred": it records only a Schneider Electric PSIRT-submitted score (source [email protected]) — CVSS v3.1 7.5 (high), vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H, and CVSS v4.0 8.7 (high) — both typed Secondary. NVD has published no Primary CVSS score of its own as of 2026-11-07, so this page does not show a headline severity figure of its own, rather than presenting the vendor's number as an NVD-confirmed rating (NVD).

CISA's advisory ICSA-26-260-04, which republishes Schneider Electric's own security notification SEVD-2025-224-05 (originally published August 12, 2025) with CISA's own update dated September 17, 2026, states the impact plainly: "Failure to apply the fix provided below may risk Denial Of Service attack, which could result in the unavailability of the devices" (CISA ICS Advisory ICSA-26-260-04).

Schneider's fix ships as BMXNOE0100 version 3.60, BMXNOE0110 version 6.80, Modicon M340 controller firmware SV3.70, and BMXNOR0200H version SV1.7_IR27; the advisory lists the M580 Global Data module and the Modicon M340 X80 Ethernet communication modules as affected in all versions without naming a specific fixed release for either. Until a device is patched, CISA notes "FTP service is disabled by default" and recommends operators "ensure to disable FTP service when not in use," segment the network and firewall off port 21/FTP from unauthorized access, and use a VPN tunnel for any required remote access (CISA ICS Advisory ICSA-26-260-04).

This CVE is not listed in the CISA Known Exploited Vulnerabilities catalog as of catalog version 2026.11.06, and FIRST scores the probability of exploitation at 0.0050 (43.0th percentile) as of 2026-11-06 (CISA KEV, FIRST EPSS).

NVD has not finished its own severity analysis of this flaw. In the meantime, Modicon M340 operators should update the listed modules to the fixed versions where available, confirm FTP remains disabled unless actively needed, and restrict network access to port 21 on any device that cannot be patched immediately.

How to fix this class of issueNo dedicated SoftWSP guide covers this weakness class; the fix is usually the vendor patch or firmware update referenced above. Our related guide explains how to plan and verify it: NIST SP 800-40 Rev. 4: enterprise patch management planning, explained.

Evidence

  • An improper input validation vulnerability (CWE-20) that could cause a denial of service when a specific crafted FTP command is sent to the device. — NVD
  • Affected products: Modicon M340 Controller firmware before SV3.70, BMXNOE0100 before 3.60, BMXNOE0110 before 6.80, BMXNOR0200H before SV1.7_IR27, M580 Global Data module (all versions), Modicon M340 X80 Ethernet communication modules (all versions). — CISA ICS Advisory ICSA-26-260-04
  • NVD status is 'Deferred' with a Schneider Electric PSIRT-submitted Secondary CVSS v3.1 7.5 / v4.0 8.7; no NVD-published Primary score. — NVD
  • "Failure to apply the fix provided below may risk Denial Of Service attack, which could result in the unavailability of the devices." FTP is disabled by default; mitigations include disabling FTP when unused, firewalling port 21, and using a VPN for remote access. — CISA ICS Advisory ICSA-26-260-04
  • Not present in the CISA KEV catalog as of catalog version 2026.11.06; EPSS score is 0.0050 (43.0th percentile) as of 2026-11-06. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICS Advisory ICSA-26-260-04
  3. Schneider Electric Security Notification SEVD-2025-224-05
  4. CISA KEV
  5. FIRST EPSS

Frequently asked questions

What is CVE-2025-6625?

CVE-2025-6625 is a denial-of-service vulnerability (CWE-20, improper input validation) in Schneider Electric's Modicon M340 programmable logic controller and its companion X80 Ethernet/Modbus communication modules: sending a specially crafted FTP command to the device's FTP service can crash it, and because NVD's own analysis of this CVE is still deferred, the CVSS scores shown in sourcing below come from Schneider's own PSIRT submission rather than an NVD-confirmed rating.

How severe is CVE-2025-6625?

CVE-2025-6625 has no NVD CVSS score published as of 2026-11-10, so this page gives it no severity rating rather than assuming low or high risk.

Is CVE-2025-6625 being actively exploited?

CVE-2025-6625 is not listed in the CISA Known Exploited Vulnerabilities (KEV) catalog. FIRST's EPSS model puts its probability of exploitation at 0.50%.

What is affected by CVE-2025-6625?

CVE-2025-6625 affects Schneider Electric Modicon M340 Controller and companion X80 Ethernet/Modbus communication modules (BMXNOE0100, BMXNOE0110, BMXNOR0200H Ethernet/Serial RTU module, M580 Global Data module).

Where does this CVE-2025-6625 information come from?

This advisory is based on NVD, CISA ICS Advisory ICSA-26-260-04, Schneider Electric Security Notification SEVD-2025-224-05, CISA KEV, and FIRST EPSS, cited in full in the Sources section above.