Security Advisory

CVE-2025-10880: Dingtian DT-R002 Password Leak

Last updated:
  • CVE-2025-10880

CVE-2025-10880 is an insufficiently protected credentials flaw in every version of the Dingtian DT-R002 relay board: an unauthenticated GET request returns the password of the proprietary Dingtian Binary control protocol. NVD scores it 7.5. Dingtian did not respond to CISA and no fix exists; researchers advise restricting TCP/80 and UDP/60000-60001.

Vulnerability summary

CVSS base score

7.5

High severity

EPSS score (FIRST)

0.5%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2025-10880 · Source: NVD

Affected components

ComponentCPEVersion range
Dingtian DT-R002 2-channel relay boardcpe:2.3:o:dingtian-tech:dt-r002_firmware:-:*:*:*:*:*:*:*All versions per CISA ICSA-25-268-01 and NVD; no vendor fix, restrict TCP/80 and UDP/60000-60001

What does this mean for affected devices?

CVE-2025-10880 is an insufficiently protected credentials flaw (CWE-522) in the Dingtian DT-R002 relay board. NVD's description reads: "All versions of Dingtian DT-R002 are vulnerable to an Insufficiently Protected Credentials vulnerability that could allow an attacker to extract the proprietary 'Dingtian Binary' protocol password by sending an unauthenticated GET request" (NVD).

NVD's Primary score is CVSS v3.1 7.5 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N), the same vector CISA uses in its CSAF file. CISA, the CNA, also gives CVSS v4 8.7. NVD matches the firmware CPE cpe:2.3:o:dingtian-tech:dt-r002_firmware (all versions) running on the DT-R002 hardware (CVE record).

What is the DT-R002?

Dingtian's product page lists the DT-R002 as a 2-channel relay board with digital inputs and outputs, Ethernet, Wi-Fi, RS485 and CAN interfaces, and protocols including HTTP GET/CGI, Modbus RTU/ASCII/TCP, MQTT and CoAP, with integrations for home automation systems such as Home Assistant (Dingtian). The leaked password is the one for the board's proprietary Dingtian Binary protocol, so once it is exposed that protocol's password check no longer keeps anyone out; CISA's risk evaluation is that an attacker can retrieve credentials without authentication. CISA lists the sector as Critical Manufacturing, deployed worldwide, with the vendor headquartered in China.

Is there a firmware fix?

No fix is listed. CISA's advisory ICSA-25-268-01 states: "Dingtian has not responded to requests to work with CISA to mitigate these vulnerabilities," and invites users to contact Dingtian customer support. The researchers, Nicolas Cano and Reid Wightman of Dragos, recommend restricting access to HTTP (TCP/80) and the Dingtian protocol on UDP/60000 and UDP/60001 (CSAF file). In practice: put the board on an isolated control network, block those ports from every host that does not need them, and never expose the board to the internet.

The same advisory lists CVE-2025-10879, which lets an unauthenticated attacker retrieve the current user's username (CWE-522, NVD 5.3). The Modbus protocol security guide covers why unauthenticated control protocols need network-level protection, and the authentication bypass fix guide covers protecting credentials in device web servers.

How urgent is it?

CVE-2025-10880 is not in the CISA Known Exploited Vulnerabilities catalog as of 2026-11-26 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS gives it 0.00536, the 38.7th percentile, in the 2026-11-25 dataset (CISA KEV, FIRST EPSS). With no vendor fix, network restrictions are the only control; the OT security guide for small manufacturers covers segmenting devices like this one.

How to fix this class of issueNo dedicated SoftWSP guide covers this weakness class; the fix is usually the vendor patch or firmware update referenced above. Our related guide explains how to plan and verify it: NIST SP 800-40 Rev. 4: enterprise patch management planning, explained.

Evidence

  • All DT-R002 versions let an unauthenticated GET request extract the Dingtian Binary protocol password. — NVD
  • NVD Primary CVSS v3.1 7.5, CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N; CISA CNA CVSS v4 8.7. — NVD
  • Dingtian did not respond to CISA; researchers recommend restricting TCP/80 and UDP/60000-60001. — CISA CSAF ICSA-25-268-01
  • DT-R002 is a 2-channel relay board with Ethernet, Wi-Fi, RS485 and CAN, supporting Modbus, MQTT and CoAP. — Dingtian
  • Not in CISA KEV as of 2026-11-26; EPSS 0.00536 (38.7th percentile) in the 2026-11-25 dataset. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CVE.org record CVE-2025-10880
  3. CISA ICSA-25-268-01
  4. CISA CSAF: ICSA-25-268-01 (machine-readable advisory)
  5. Dingtian: DT-R002 2-channel relay board
  6. CISA KEV
  7. FIRST EPSS

Frequently asked questions

Is there a firmware update for CVE-2025-10880?

No fix is listed as of 2026-11-26. CISA ICSA-25-268-01 states that Dingtian has not responded to requests to work with CISA, and all DT-R002 versions are listed as affected (per the CISA CSAF and NVD).

How can DT-R002 owners reduce the risk?

The researchers from Dragos recommend restricting access to HTTP on TCP/80 and to the Dingtian protocol on UDP/60000 and UDP/60001, so only the hosts that control the board can reach it (per the CISA CSAF).

What does an attacker gain from the leaked password?

The password for the proprietary Dingtian Binary protocol on a relay board that switches outputs, so the protocol's password check stops protecting the board; CISA's risk evaluation is that an attacker can retrieve credentials without authentication (per NVD, the CISA CSAF and Dingtian's product page).

Is CVE-2025-10880 exploited in the wild?

It is not in the CISA KEV catalog as of 2026-11-26 (catalog version 2026.11.25). FIRST EPSS gives it 0.00536, the 38.7th percentile, in the 2026-11-25 dataset (per CISA KEV and FIRST EPSS).