CVE-2021-38432 is a stack-based buffer overflow in FATEK Automation Communication Server, an OT software product from the PLC maker FATEK. Versions 1.13 and prior do not validate user-supplied data, so a remote attacker could execute code. NVD and CISA score it 9.8. FATEK did not respond to CISA, and no fixed version is listed.
Vulnerability summary
CVSS base score
9.8
Critical severity
EPSS score (FIRST)
1.9%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2021-38432 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| FATEK Automation Communication Server | cpe:2.3:o:fatek:communication_server_firmware:*:*:*:*:*:*:*:* | 1.13 and prior (NVD, CISA ICSA-21-280-07); no fixed version listed, FATEK did not respond to CISA; mitigate by isolating the server |
What does this mean for affected devices?
The CVE record from CISA says that FATEK Automation Communication Server versions 1.13 and prior "lacks proper validation of user-supplied data, which could result in a stack-based buffer overflow condition and allow an attacker to remotely execute code." NVD's Primary score is 9.8, CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, the same as CISA's. The weakness, CWE-121 (stack-based buffer overflow), comes from CISA; NVD lists no CWE of its own. NVD published the record on 2021-10-15. Its configuration models the product as firmware on a "communication_server" hardware platform, with every version up to 1.13 vulnerable (NVD, CVE record).
What is affected?
CISA's ICSA-21-280-07, released on 2021-10-07, covers FATEK Automation Communication Server 1.13 and prior, deployed in the Critical Manufacturing sector, with remote code execution as the risk. Natnael Samson reported the flaw. FATEK Automation is a Taiwanese maker of PLCs and HMI software; the same CISA release batch and later advisories also covered its WinProladder ladder programming tool (ICSA-21-280-06 and ICSA-21-320-01) and FvDesigner HMI editor (ICSA-21-217-02).
How do you fix CVE-2021-38432?
There is no published fix. CISA states that FATEK Automation "has not responded to requests to work with CISA to mitigate this vulnerability" and invites users to contact FATEK customer support. As of 2026-11-27 FATEK's public download centre lists OPC UA server packages but no Communication Server release. Until FATEK supplies a fixed version, apply CISA's general measures:
- keep the Communication Server host unreachable from the internet and from business networks, behind a firewall that admits only the HMI and SCADA clients that need it;
- use a current VPN for any remote access to the control network;
- if the software is no longer needed for a PLC link, remove it from the host.
Memory-safety flaws in network-facing OT software are a common pattern; compare CVE-2019-6557 in Moxa IKS web servers and CVE-2021-22659 in the Rockwell MicroLogix 1400. Our memory corruption fix guide explains how vendors remove stack overflows like this one, and the guide for small manufacturers covers segmentation when a vendor offers no patch.
Is CVE-2021-38432 exploited?
CVE-2021-38432 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS gives it 0.01870, the 79.89th percentile, in the 2026-11-26 dataset (CISA KEV, FIRST EPSS).


Evidence
- NVD (read 2026-11-27): status Modified; published 2021-10-15; NVD Primary CVSS v3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, CVSS v2 7.5; ICS-CERT Secondary 9.8; CWE-121 from ICS-CERT only; CPE cpe:2.3:o:fatek:communication_server_firmware up to 1.13 inclusive, running on cpe:2.3:h:fatek:communication_server. — NVD
- CISA ICSA-21-280-07 CSAF (released 2021-10-07, read 2026-11-27): FATEK Automation Communication Server <= 1.13; CVE-2021-38432 CWE-121 9.8; risk remote code execution; sector Critical Manufacturing; FATEK has not responded to requests to work with CISA, users invited to contact FATEK customer support; reported by Natnael Samson. — CISA ICSA-21-280-07
- CVE record (checked 2026-11-27): PUBLISHED, CNA ICS-CERT, published 2021-10-15, CNA CVSS v3.1 9.8; affected Communication Server all versions up to 1.13; workaround text: FATEK has not responded to CISA, contact FATEK support. — CVE.org
- FATEK download centre (read 2026-11-27): categories include FATEK OPC UA Server, programming software and FBs/B1 main unit software; no Communication Server entry. — FATEK Automation
- Not in the CISA KEV catalog, catalog version 2026.11.25, 1,805 entries, checked 2026-11-27. — CISA KEV
- EPSS 0.01870, percentile 0.79889, dataset 2026-11-26, read 2026-11-27. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which FATEK Communication Server versions are affected?
Version 1.13 and all earlier versions (CISA ICSA-21-280-07 and NVD).
Is there a patch for CVE-2021-38432?
No fixed version is published. CISA says FATEK did not respond to its requests, and FATEK's download centre lists no Communication Server release as of 2026-11-27. Contact FATEK support and isolate the server behind a firewall.
Which other FATEK products had CISA advisories in 2021?
WinProladder (ICSA-21-280-06 and ICSA-21-320-01) and FvDesigner (ICSA-21-217-02), both engineering tools with file-parsing memory corruption flaws.
Is CVE-2021-38432 in the CISA KEV catalog?
No, not as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS rates it 0.01870 (79.89th percentile) in the 2026-11-26 dataset.