CVE-2016-5799 is a missing limit on login attempts in Moxa OnCell cellular gateways (G3100V2 before firmware 2.8; G3111, G3151, G3211 and G3251 before 1.7), which lets a remote attacker guess credentials by brute force and take over the device. NVD and CISA both score it 9.8. Moxa released fixed firmware for both series.
Vulnerability summary
CVSS base score
9.8
Critical severity
EPSS score (FIRST)
4.0%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2016-5799 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| Moxa OnCell G3100V2 Series | cpe:2.3:o:moxa:oncell_g3100v2_firmware:*:*:*:*:*:*:*:* | Firmware before 2.8 (CISA ICSA-16-236-01A; NVD CPE up to and including 2.7); fixed in 2.8 |
| Moxa OnCell G3111/G3151/G3211/G3251 Series | cpe:2.3:o:moxa:oncell_g3001_firmware:*:*:*:*:*:*:*:* | Firmware before 1.7 (CISA ICSA-16-236-01A; NVD CPE oncell_g3001_firmware up to and including 1.6 on G3111/G3151/G3211/G3251 hardware); fixed in 1.7 |
What does this mean for affected devices?
The CVE description reads: "Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack." NVD's Primary score is 9.8 (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, CVSS 2.0 10.0) with CWE-285; CISA classes it as CWE-307, improper restriction of excessive authentication attempts. NVD's CPE configuration covers G3100V2 firmware up to and including 2.7 and, under the product name oncell_g3001_firmware, firmware up to and including 1.6 on G3111, G3151, G3211 and G3251 hardware (NVD, CVE record).
Which Moxa OnCell gateways are affected?
CISA's ICSA-16-236-01A (first released on 2016-08-23, Update A on 2018-08-23) lists:
- OnCell G3100V2 Series, firmware before 2.8;
- OnCell G3111/G3151/G3211/G3251 Series, firmware before 1.7.
The same advisory covers two sibling flaws fixed by the same firmware: CVE-2016-5812, plaintext storage of the password in a configuration file (CVSS 3.3, local), and CVE-2016-5819, reflected cross-site scripting in the web console (CVSS 6.5). CISA gives CVE-2016-5799 the same 9.8 score and vector as NVD, says the flaws are remotely exploitable by an attacker with low skill, and reported no known public exploits. Maxim Rupp reported them. CISA lists commercial facilities, critical manufacturing, energy and transportation systems, mainly in Asia and Europe.
How do you fix CVE-2016-5799?
Install OnCell G3100V2 firmware 2.8 or OnCell G3111/G3151/G3211/G3251 firmware 1.7 from Moxa's support site. Moxa's upgrade advice, quoted by CISA, is to save the configuration first and upgrade over a local LAN connection (web console, serial console or the OnCell Search Utility) so a dropped cellular link does not interrupt the update (CISA CSAF). On a cellular gateway the web console may be reachable from the carrier network, so also restrict management access to a VPN, use long unique passwords, and watch the logs for repeated failed logins.
The authentication bypass fix guide covers login throttling and lockout in device firmware, and the OT security guide for small manufacturers covers remote access. Related Moxa pages: CVE-2018-5455 (OnCell G3100-HSPA weak session cookie) and CVE-2016-9366 (NPort brute-force authentication bypass).
Is CVE-2016-5799 exploited?
CVE-2016-5799 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS gives it 0.04002, the 91.31th percentile, in the 2026-11-26 dataset (CISA KEV, FIRST EPSS).


Evidence
- NVD (read 2026-11-27): status Modified; published 2016-08-24; [email protected] Primary CVSS 3.0 9.8 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, CVSS 2.0 10.0; CWE-285; CPE moxa oncell_g3100v2_firmware <=2.7, oncell_g3001_firmware <=1.6 with G3111/G3151/G3211/G3251 hardware. — NVD
- CISA ICSA-16-236-01A (CSAF): OnCell G3100V2 <2.8, G3111/G3151/G3211/G3251 <1.7; CVE-2016-5799 CWE-307 9.8; CVE-2016-5812 CWE-256 3.3; CVE-2016-5819 CWE-79 6.5; firmware fixes on Moxa site; upgrade advice (save config, LAN connection, web/serial console or OnCell Search Utility). — CISA CSAF
- CISA ICSA-16-236-01A page: original release 2016-08-23, Update A 2018-08-23; researcher Maxim Rupp; commercial facilities, critical manufacturing, energy, transportation; mainly Asia and Europe; remote, low skill; no known public exploits. — CISA
- CVE.org record (MITRE-era format): published 2016-08-24; same description; no CNA CVSS. — CVE.org
- CISA KEV catalog version 2026.11.25, 1,805 entries: CVE-2016-5799 not listed; checked 2026-11-27. — CISA KEV
- EPSS 0.04002, percentile 0.91306, dataset 2026-11-26, read 2026-11-27. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which OnCell firmware fixes CVE-2016-5799?
Firmware 2.8 for the OnCell G3100V2 Series and firmware 1.7 for the OnCell G3111/G3151/G3211/G3251 Series, per CISA ICSA-16-236-01A.
What other flaws does the same Moxa update fix?
CVE-2016-5812 (password stored in plaintext in a configuration file, CVSS 3.3) and CVE-2016-5819 (reflected cross-site scripting in the web console, CVSS 6.5).
How should the firmware be installed?
Moxa advises saving the configuration first and upgrading over a local LAN connection through the web console, serial console or OnCell Search Utility, so the update is not interrupted.
Is CVE-2016-5799 in the CISA KEV catalog?
No, not as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS rates it 0.04002, the 91.31th percentile, in the 2026-11-26 dataset.
Questions about this page?